Summary
ABB is aware of vulnerabilities in the product versions listed as affected in the advisory.
An attacker who successfully exploited this vulnerability could cause the pollution of heap memory which potentially takes remote control of the product and performs a write operation to the flash memory to alter the firmware behavior.
Vulnerabilities 1
-
Critical 10.0
Missing Authentication Vulnerability
Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects . All firmware versions with the Serial Number from 2000 to 5166
Revision history
-
#2
Updated CVSS 3.1 score
-
#1
Initial version.
References
-
ABB CYBERSECURITY ADVISORY - PDF Version
https://search.abb.com/library/Download.aspx?DocumentID=4TZ00000006007&LanguageCode=en&DocumentPartId=PDF&Action=Launch
-
19014 v2.1 Product user manual - ALS-mini-s (IP) Technisches Handbuch