Summary
Successful exploitation of these vulnerabilities could result in unauthorized password changes, escalation of privileges, falsifying of password logs, and bypassing of web access controls.
Vulnerabilities 3
-
Critical 9.8
Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monito…
-
Critical 9.1
Cognex 3D-A1000 Dimensioning System Client-Side Enforcement of Server-Side Security
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-602: Client-Side Enforcement of Server-Side Security, which could allow attackers to bypass web access controls by inspecting and modifying the source code…
-
Medium 5.3
Cognex 3D-A1000 Dimensioning System Improper Output Neutralization for Logs
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-117: Improper Output Neutralization for Logs, which allows an attacker to create false logs that show the password as having been changed when it is not, c…
Revision history
-
#1
Publication Date
References
-
ICS Advisory ICSA-22-249-03 Web Version
https://www.cisa.gov/news-events/ics-advisories/icsa-22-249-03
-
Recommended Practices
https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
-
Recommended Practices
https://www.cisa.gov/news-events/ics-advisories/icsa-22-249-03
-
Recommended Practices
https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf