Summary
QMS Automotive before V12.39 contains multiple vulnerabilities that could allow an attacker to perform malicious code injection, information disclosure or lead to a denial of service condition.
Siemens has released an update for QMS Automotive and recommends to update to the latest version.
Vulnerabilities 10
-
High 8.8
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The affected application server responds…
-
High 7.8
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The QMS.Mobile module of the affected ap…
-
High 7.6
A vulnerability has been identified in QMS Automotive (All versions < V12.39), QMS Automotive (All versions < V12.39). …
-
High 7.3
A vulnerability has been identified in QMS Automotive (All versions < V12.39). User credentials are found in memory as …
-
High 7.3
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The QMS.Mobile module of the affected ap…
-
High 7.3
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The affected application lacks security …
-
High 7.1
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The QMS.Mobile module of the affected ap…
-
Medium 5.7
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The affected application allows users to…
-
Medium 4.0
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The affected application returns inconsi…
-
Low 3.9
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The QMS.Mobile module of the affected ap…
Revision history
-
#2
Revision - Fixing typos
-
#1
Publication Date
References
-
SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - HTML Version
https://cert-portal.siemens.com/productcert/html/ssa-147266.html
-
SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - PDF Version
https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf
-
SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - TXT Version
https://cert-portal.siemens.com/productcert/txt/ssa-147266.txt
-
ICS Advisory ICSA-23-257-03 - Web Version
https://www.cisa.gov/news-events/ics-advisories/icsa-23-257-03
-
Recommended Practices
https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
-
Recommended Practices
https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
-
Recommended Practices
https://www.cisa.gov/topics/industrial-control-systems
-
Recommended Practices
https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
-
Recommended Practices
https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
-
Recommended Practices
https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B