Skip to content
OpenAdvisories
Critical ICSA-25-296-03 2 CVEs

Veeder-Root TLS4B Automatic Tank Gauge System

Published Oct 23, 2025 · Updated Oct 23, 2025

Summary

Successful exploitation of these vulnerabilities could allow attackers to execute system-level commands, gain full shell access, achieve remote command execution, move laterally within the network, trigger a denial of service condition, cause administrative lockout, and disrupt core system functionalities.

Vulnerabilities 2

  • Critical 9.9

    Command Injection in Veeder-Root TLS4B Automatic Tank Gauge System

    The TLS4B ATG system's SOAP-based interface is vulnerable due to its accessibility through the web services handler. This vulnerability enables remote attackers with valid credentials to execute system-level commands on the underlying Linux system. This could…

  • High 7.1

    Integer Overflow or Wraparound in Veeder-Root TLS4B Automatic Tank Gauge System

    The TLS4B ATG system is vulnerable to improper handling of Unix time values that exceed the 2038 epoch rollover. When the system clock reaches January 19, 2038, it resets to December 13, 1901, causing authentication failures and disrupting core system functio…

Revision history

  1. #1

    Initial Publication

References