Summary
Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks.
Vulnerabilities 4
-
Critical 9.4
Everon api.everon.io Missing Authentication for Critical Function
WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discov…
-
High 7.5
Everon api.everon.io Improper Restriction of Excessive Authentication Attempts
The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, o…
-
High 7.3
Everon api.everon.io Insufficient Session Expiration
The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or …
-
Medium 6.5
Everon api.everon.io Insufficiently Protected Credentials
Charging station authentication identifiers are publicly accessible via web-based mapping platforms.
Revision history
-
#1
Initial Publication
References
-
ICSA Advisory ICSA-26-062-08 - Web Version
https://www.cisa.gov/news-events/ics-advisories/icsa-26-062-08
-
Recommended Practices
https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
-
Recommended Practices
https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
-
Recommended Practices
https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
-
Recommended Practices
https://www.cisa.gov/topics/industrial-control-systems
-
Recommended Practices
https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
-
Recommended Practices
https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
-
Recommended Practices
https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b
-
Recommended Practices
https://www.cisa.gov/secure-our-world/teach-employees-avoid-phishing
-
Recommended Practices
https://www.cisa.gov/news-events/news/avoiding-social-engineering-and-phishing-attacks