Skip to content
OpenAdvisories
High ICSA-26-258-08 7 CVEs

CareCam CM2507

Published Sep 15, 2026 · Updated Sep 15, 2026

Summary

Successful exploitation of these vulnerabilities could allow an attacker to access live video and sensitive device information, enable unauthorized services, execute arbitrary code, modify device operation, and recover stored credentials.

Vulnerabilities 7

  • Critical 9.8

    CareCam CM2507 Cleartext Storage of Sensitive Information

    CM2507 IP cameras store configured wireless network credentials in cleartext within the device filesystem. An attacker who obtains filesystem access through physical access, a debugging interface, or another vulnerability could recover the configured network …

  • Critical 9.8

    CareCam CM2507 Use of Password Hash With Insufficient Computational Effort

    CareCam CM2507 IP cameras store the device's root-account password using a fixed legacy password hash that provides insufficient resistance to offline cracking. An attacker who obtains the firmware image or password database could recover the associated crede…

  • High 7.5

    CareCam CM2507 Empty Password in Configuration File

    CM2507 IP cameras accept an empty password for a privileged account exposed through its ONVIF management service. An attacker with network access to the affected device could access privileged management functions and obtain device, user, media-profile, and s…

  • High 7.5

    CareCam CM2507 Missing Authentication for Critical Function

    CareCam CM2507 IP cameras do not require authentication for access to its network video streaming service. An unauthenticated attacker with network access to the affected device could retrieve live camera video.

  • Medium 6.8

    CareCam CM2507 Inclusion of Functionality from Untrusted Control Sphere

    CM2507 IP cameras automatically execute a predetermined script from removable media without verifying its authenticity or integrity. An attacker with physical access to the device could supply a malicious script and execute arbitrary code in the security cont…

  • Low 3.5

    CareCam CM2507 Missing Authentication for Critical Function

    A CM2507 IP camera running firmware version HMT.CM2507 v251211.1507 exposes an interactive bootloader through a physical debug interface without requiring authentication. An attacker with physical access could interrupt the normal boot process and access func…

  • Low 3.1

    CareCam CM2507 Missing Authentication for Critical Function

    CareCam CM2507 IP cameras contain an insufficiently protected network maintenance mechanism that can activate a remote debugging service. An attacker on the same local network who satisfies certain device state conditions could make the service remotely acces…

Revision history

  1. #1

    Initial Publication

References