Skip to content
OpenAdvisories
Critical SCA-2025-0004 3 CVEs

Critical vulnerabilities in SICK DL100-2xxxxxxx

Published Mar 14, 2025 · Updated Mar 14, 2025 · Revision 2

Summary

Critical vulnerabilities have been found in the SICK device DL100-2xxxxxxx. If exploited, this potentially allows an attacker to impact availabiltiy, integrity and confidentaility of the products. Currently, SICK is not aware of any public exploits specifically targeting these vulnerabilities. As a mitigation, SICK strongly recommends operating the system within a secure infrastructure to minimize risk.

Vulnerabilities 3

  • Critical 9.8

    Weak hashing alghrythm

    The device uses a weak hashing alghorithm to create the password hash. Hence, a matching password can be easily calculated by an attacker. This impacts the security and the integrity of the device.

  • Critical 9.3

    RCE due to Device Driver

    The product can be used to distribute malicious code using SDD Device Drivers due to missing download verification checks, leading to code execution on target systems.

  • High 7.5

    Unencrypted transmission of password hash

    The device uses an unencrypted, proprietary protocol for communication. Through this protocol, configuration data is transmitted and device authentication is performed. An attacker can thereby intercept the authentication hash and use it to log into the devic…

Revision history

  1. #2

    Updated Advisory: URL for SICK Operating Guidelines has been updated

  2. #1

    Initial version

References