Summary
Schneider Electric is aware of multiple vulnerabilities in Redis open-source database, affecting its Plant iT product.
The [Plant iT/Brewmaxx](https://www.proleit.com/plant-it/) product is an object-oriented and PLC-based process control system with integrated
Manufacturing Execution System functionality. The integrated and modular software platform consists of basic
systems, modules and add-ons that can be flexibly combined.
Failure to apply the remediations provided below may risk privilege escalation, which could result in remote
code execution.
Vulnerabilities 4
-
Critical 10.0
Redis Lua Use-After-Free may lead to remote code execution
Redis is an open source, in-memory database that persists on disk. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate the garbage collector, trigger a use-after-free and potentially lead to remote code exe…
-
High 7.0
Lua library commands may lead to integer overflow and potential RCE
Redis is an open source, in-memory database that persists on disk. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to cause an integer overflow and potentially lead to remote code execution The problem exists in all …
-
Medium 6.3
Redis is vulnerable to DoS via specially crafted LUA scripts
Redis is an open source, in-memory database that persists on disk. Versions 8.2.1 and below allow an authenticated user to use a specially crafted LUA script to read out-of-bound data or crash the server and subsequent denial of service. The problem exists in…
-
Medium 6.0
Redis: Authenticated users can execute LUA scripts as a different user
Redis is an open source, in-memory database that persists on disk. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate different LUA objects and potentially run their own code in the context of another user…
Revision history
-
#2.0.0
Updated the CWE description of CVE-2025-46819
-
#1.0.0
Original Release
References
-
Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx - SEVD-2026-013-01 PDF Version
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-01.pdf
-
Recommended Cybersecurity Best Practices
https://www.se.com/ww/en/download/document/7EN52-0390/