Summary
SINUMERIK ONE and SINUMERIK MC products are affected by a denial of service vulnerability in the OPC UA implementation of the integrated S7-1500 CPU. The vulnerability in the integrated S7-1500 CPU is documented in more detail in SSA-711309 [1].
Siemens has released updates for the affected products and recommends to update to the latest versions.
[1]
https://cert-portal.siemens.com/productcert/html/ssa-711309.html
Vulnerabilities 1
-
High 7.5
The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could c…
Revision history
-
#1
Publication Date
References
-
SSA-118850: Denial of Service Vulnerability in the OPC UA Implementation in SINUMERIK ONE and SINUMERIK MC - HTML Version
https://cert-portal.siemens.com/productcert/html/ssa-118850.html
-
SSA-118850: Denial of Service Vulnerability in the OPC UA Implementation in SINUMERIK ONE and SINUMERIK MC - PDF Version
https://cert-portal.siemens.com/productcert/pdf/ssa-118850.pdf
-
SSA-118850: Denial of Service Vulnerability in the OPC UA Implementation in SINUMERIK ONE and SINUMERIK MC - TXT Version
https://cert-portal.siemens.com/productcert/txt/ssa-118850.txt