Summary
Several SIMATIC products are affected by a type confusion vulnerability relating to OpenSSL X.400 address processing (CVE-2023-0286), as disclosed disclosed on 2023-02-07 at
https://www.openssl.org/news/secadv/20230207.txt.
Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
Vulnerabilities 1
-
High 7.4
X.400 address type confusion in X.509 GeneralName
There is a type confusion vulnerability relating to X.400 address processing inside an X.509 GeneralName. X.400 addresses were parsed as an ASN1_STRING but the public structure definition for GENERAL_NAME incorrectly specified the type of the x400Address fiel…
Revision history
-
#4
Added fix for SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V30 and SIMATIC S7-1500 Software Controller V3
-
#3
Clarified that no fix is planned for SIMATIC IPC DiagBase and SIMATIC IPC DiagMonitor; Added fix for SIMATIC S7-PLCSIM Advanced
-
#2
Clarified SIMATIC ET 200SP Open Controller versions and added fix for SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants); Clarified SIMATIC S7-1500 Software Controller versions and added fix for SIMATIC S7-1500 Software Controller V2
-
#1
Publication Date
References
-
SSA-264815: Type Confusion Vulnerability in OpenSSL X.400 Address Processing in SIMATIC Products - HTML Version
https://cert-portal.siemens.com/productcert/html/ssa-264815.html