Summary
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC. This advisory lists the related Siemens Industrial products affected by these vulnerabilities.
Siemens recommends to contact customer support to receive patch and update information.
Vulnerabilities 5
-
High 7.5
Disabled and non-configurable certificate/host key validation in Smart Polling in Guardian/CMC before 26.3.0 and Arc before v2.7.0
An improper certificate/host key validation vulnerability was discovered in the Smart Polling functionality, which established encrypted connections to target devices without validating the remote host's identity, and no option was provided to enable it. A ma…
-
High 7.4
Incorrect authorization in Credentials Manager in Guardian/CMC before 26.3.0
An access control vulnerability was discovered in the Credentials Manager functionality due to insufficient validation of user privileges. A remote authenticated user with limited privileges can view a limited subset of the available entries in the Credential…
-
Medium 5.4
Incorrect authorization in Smart Polling configuration in Guardian/CMC before 26.3.0
An access control vulnerability was discovered in the Smart Polling configuration functionality due to insufficient validation of user privileges. An authenticated user with limited privileges can remotely bypass the intended access control of the web managem…
-
Medium 4.6
Insufficient sanitization of Dashboards in Guardian/CMC before 26.3.0
A template injection vulnerability was discovered in the Dashboards functionality due to improper validation of an input parameter. An authenticated user with the required privileges can define a dashboard containing a malicious payload, or a victim can be so…
-
Low 3.5
Cross-site request forgery in the Guardian/CMC login before 26.3.0
A cross-site request forgery vulnerability was discovered in the login functionality (both standard and SAML) due to missing validation of the anti-CSRF token. An attacker with a valid account can trick a victim into unknowingly authenticating with the attack…
Revision history
-
#1
Publication Date
References
-
SSA-911336: Multiple Vulnerabilities in Nozomi Guardian/CMC on RUGGEDCOM APE1808 Devices - HTML Version
https://cert-portal.siemens.com/productcert/html/ssa-911336.html