Summary
The Mendix Encryption module versions V10.0.0 and V10.0.1 define a specific hard-coded default value for the EncryptionKey constant, which is used in projects where no individual EncryptionKey was specified. This could allow to an attacker to decrypt any encrypted project data, as the default encryption key can be considered compromised.
Siemens has released a new version for Mendix Encryption and recommends to update to the latest version.
Vulnerabilities 1
-
High 7.5
A vulnerability has been identified in Mendix Encryption (All versions >= V10.0.0 < V10.0.2). Affected versions of the …
Revision history
-
#1
Publication Date
References
-
SSA-998949: Hard-coded Default Encryption Key in Mendix Encryption Module V10.0.0 and V10.0.1 - HTML Version
https://cert-portal.siemens.com/productcert/html/ssa-998949.html
-
SSA-998949: Hard-coded Default Encryption Key in Mendix Encryption Module V10.0.0 and V10.0.1 - PDF Version
https://cert-portal.siemens.com/productcert/pdf/ssa-998949.pdf
-
SSA-998949: Hard-coded Default Encryption Key in Mendix Encryption Module V10.0.0 and V10.0.1 - TXT Version
https://cert-portal.siemens.com/productcert/txt/ssa-998949.txt