Summary
VARTA energy storage systems have a web user interface via which users and installers can access live data measurements and configure the system to their needs. It has been discovered that the corresponding credentials are hard-coded within the frontend and thus potentially exploitable.
Details
Impact
The vulnerability allows unauthorized read and write access to the web backend. This allows reading and writing of parameters that are not intended for this purpose (e.g. connectivity settings, grid parameters). This can impact the operational availability and integrity. The safety of the battery storage device is not affected because safety relevant parameters are not accessible via the web backend.
Mitigation
General countermeasures: Restrict HTTP traffic to the energy storage system by using an inbound firewall or other measures on the network level.
Remediation
A fixed version will be rolled out OTA as soon as it is available. Rollout for VARTA element backup will start end of Q1/2023 followed by Element S4.
Vulnerabilities 1
-
Critical 9.8
VARTA: Multiple devices prone to hard-coded credentials
Hard-coded credentials in Web-UI of multiple VARTA Storage products in multiple versions allows an unauthorized attacker to gain administrative access to the Web-UI via network.
Revision history
-
#1
Initial revision.
References
-
VDE-2022-061: VARTA: Multiple devices prone to hard-coded credentials - HTML
https://certvde.com/en/advisories/VDE-2022-061/
-
VARTA PSIRT
https://varta-storage.com
-
CERT@VDE Security Advisories for VARTA Storage GmbH
https://certvde.com/en/advisories/vendor/varta-storage/