Skip to content
OpenAdvisories
High VDE-2026-068 1 CVE

MB connect line: Authenticated unintended access to critical program parameters in mbCONNECT24/mymbCONNECT24

Published Jun 23, 2026 · Updated Jun 23, 2026

Summary

There is a vulnerability in mbCONNECT24/mymbCONNECT24 that allows an authenticated remote attacker to access a hidden configuration method, that should not be accessible by any user, to modify critical program parameters.

Details

Impact
CVE-2026-10521 allows an authenticated remote attacker to modify critical program parameters. This can result in a total loss of confidentiality, integrity and availability.

Remediation
Update the mbCONNECT24/mymbCONNECT24 instance to version 2.20.2.

Vulnerabilities 1

  • High 7.2

    Authenticated unintended access to critical program parameters

    An high privileged remote attacker can access a hidden configuration method, that should not be accessible by any user, to modify critical program parameters. This can result in a total loss of confidentiality, integrity and availability.

Revision history

  1. #1.0.0

    Initial revision.

References