Critical 10.0CVE-2021-27460 Public exploit
Rockwell Automation FactoryTalk AssetCentre Deserialization of Untrusted Data
Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier components contain .NET remoting endpoints that deserialize untrusted data without sufficiently verifying that the resulting data will be valid. This vulnerability may allow a remote, unauthentica…
-
Unscored —CVE-2021-42023 Public exploit
A vulnerability has been identified in ModelSim Simulation (All versions), Questa Simulation (All versions). The RSA wh…
-
High 7.3
Rockwell Automation FactoryTalk View SE
In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enab…
-
Medium 4.3
Rockwell Automation FactoryTalk View SE
All versions of FactoryTalk View SE disclose the hostnames and file paths for certain files within the system. A remote, authenticated attacker may be able to leverage this information for reconnaissance efforts. Rockwell Automation recommends enabling built …
-
Critical 9.0
Rockwell Automation FactoryTalk View SE
All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. A remote, unauthenticated attacker may be able to execute a crafted file on a remote endpoint that may result in remote code execution (RCE). Rockwell …
-
Unscored —
ABB MicroSCADA Pro SYS600 Missing Authentication for Critical Function
ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function.
-
Unscored —CVE-2019-10915 Public exploit
A vulnerability has been identified in TIA Administrator (All versions < V1.0 SP1 Upd1). The integrated configuration w…
-
Unscored —
The vulnerability is due to insufficient handling of update_file request parameter on update_module.php in Schneider El…
-
Unscored —
The web server in Phoenix Contact ILC PLCs can be accessed without authenticating even if the authentication mechanism …
-
Unscored —
The web server in Phoenix Contact ILC PLCs allows access to read and write PLC variables without authentication.
-
Unscored —CVE-2016-8366 Public exploit
Webvisit in Phoenix Contact ILC PLCs offers a password macro to protect HMI pages on the PLC against casual or coincide…
-
Critical 10.0
Phoenix Contact Software ProConOs and MultiProg Missing Authentication for Critical Function
Phoenix Contact ProConOs and MultiProg do not require authentication, which allows remote attackers to execute arbitrary commands via protocol-compliant traffic.
-
High 8.3
Yokogawa CENTUM CS 3000 Stack-based Buffer Overflow
Stack-based buffer overflow in BKESimmgr.exe in the Expanded Test Functions package in Yokogawa CENTUM CS 1000, CENTUM CS 3000 Entry Class R3.09.50 and earlier, CENTUM VP R5.03.00 and earlier, CENTUM VP Entry Class R5.03.00 and earlier, Exaopc R3.71.02 and ea…
-
High 8.3
Yokogawa CENTUM CS 3000 Stack-based Buffer Overflow
Stack-based buffer overflow in BKBCopyD.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via a crafted TCP packet.
-
Critical 9.3
Yokogawa CENTUM CS 3000 Heap-based Buffer Overflow
Heap-based buffer overflow in BKCLogSvr.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via crafted UDP packets.
-
Critical 9.0
Yokogawa CENTUM CS 3000 Stack-based Buffer Overflow
Stack-based buffer overflow in BKHOdeq.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via a crafted TCP packet.