ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researcher…
-
High 7.5
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attac…
-
High 7.5
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 151…
-
High 7.5
A vulnerability has been identified in SIMATIC S7-300 CPUs (All versions < V3.X.16). The affected CPUs improperly valid…
-
High 7.5
Mitsubishi Electric MELSEC-Q Series PLCs Resource Exhaustion
Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attacker can send specific bytes over Port 5…
-
High 7.5
A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (A…
-
High 8.2
A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (A…
-
High 8.2
A Insufficient Verification of Data Authenticity (CWE-345) vulnerability exists in the Modicon M221, all versions, whic…
-
High 7.5
A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all re…
-
High 8.8
After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to write to the device under certain…
-
High 7.5
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be …
-
High 7.5
An exploitable null pointer dereference exists in the Web Application functionality of Moxa AWK-3131A Wireless Access P…
-
High 7.5
An exploitable null pointer dereference vulnerability exists in the Web Application /forms/web_runScript iw_filename fu…
-
High 7.5
An exploitable Cross-Site Request Forgery vulnerability exists in the Web Application functionality of Moxa AWK-3131A W…
-
High 7.5
An exploitable Cleartext Transmission of Password vulnerability exists in the Web Application functionality of Moxa AWK…
-
High 7.5
An exploitable reflected Cross-Site Scripting vulnerability exists in the Web Application functionality of Moxa AWK-313…
-
High 7.5
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. relat…
-
High 7.5
Schneider Electric Device Type Managers (DTMs) Stack-based Buffer Overflow
Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Commu…
-
High 7.1
Rockwell Automation Micrologix 1400 Improper Input Validation
The DNP3 feature on Rockwell Automation Allen-Bradley MicroLogix 1400 1766-Lxxxxx A FRN controllers 7 and earlier and 1400 1766-Lxxxxx B FRN controllers before 15.001 allows remote attackers to cause a denial of service (process disruption) via malformed pack…
-
High 7.8
Schneider Electric Wonderware Inadequate Encryption Strength
Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows remote attackers to obtain sensitive information by reading a credential file.
-
High 7.5
Schneider Electric Wonderware Cross-site Scripting
Cross-site scripting (XSS) vulnerability in Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
-
High 7.5
Schneider Electric Wonderware SQL Injection
SQL injection vulnerability in Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
-
High 8.3
Yokogawa CENTUM CS 3000 Stack-based Buffer Overflow
Stack-based buffer overflow in BKESimmgr.exe in the Expanded Test Functions package in Yokogawa CENTUM CS 1000, CENTUM CS 3000 Entry Class R3.09.50 and earlier, CENTUM VP R5.03.00 and earlier, CENTUM VP Entry Class R5.03.00 and earlier, Exaopc R3.71.02 and ea…
-
High 8.3
Yokogawa CENTUM CS 3000 Stack-based Buffer Overflow
Stack-based buffer overflow in BKBCopyD.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via a crafted TCP packet.
-
High 7.5CVE-2012-6438 EPSS 36%
Rockwell Automation ControlLogix PLC Improper Input Validation
The device does not properly validate the data being sent to the buffer. An attacker can send a malformed CIP packet to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP, which creates a buffer overflow and causes the NIC to crash. Successful ex…
-
High 8.5CVE-2012-6439 EPSS 23%
Rockwell Automation ControlLogix PLC Improper Access Control
When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that changes the product’s configuration and network parameters, a DoS condition can occur. This…
-
High 7.5CVE-2012-6435 EPSS 43%
Rockwell Automation ControlLogix PLC Improper Access Control
When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that instructs the CPU to stop logic execution and enter a fault state, a DoS can occur. This si…
-
High 7.5CVE-2012-6442 EPSS 35%
Rockwell Automation ControlLogix PLC Improper Access Control
When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that instructs the product to reset, a DoS can occur. This situation could cause loss of availab…
-
High 7.5CVE-2012-6436 EPSS 35%
Rockwell Automation ControlLogix PLC Improper Input Validation
The device does not properly validate the data being sent to the buffer. An attacker can send a malformed CIP packet to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP, which creates a buffer overflow and causes the CPU to crash. Successful ex…