Medium 6.8
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allow…
-
Medium 6.8
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087…
-
Medium 5.6
Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 …
-
Medium 5.3
Denial-of-Service (DoS) Vulnerability in FTP Server Function on GOT2000 Series
Improper Input Validation vulnerability in Mitsubishi Electric GOT2000 Series GT27 model FTP server versions 01.39.000 and prior, Mitsubishi Electric GOT2000 Series GT25 model FTP server versions 01.39.000 and prior and Mitsubishi Electric GOT2000 Series GT23…
-
Medium 5.3
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server ho…
-
Medium 6.1
Cross-site scripting vulnerability in Mitsubishi Electric consumer electronics products (Air Conditioning, Wi-Fi Interf…
-
Medium 6.5
The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenti…
-
Medium 5.3
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD…
-
Medium 6.2
Honeywell SoftMaster Incorrect Permission Assignment for Critical Resource
A local unprivileged attacker may escalate to administrator privileges in Honeywell SoftMaster version 4.51, due to insecure permission assignment.
-
Medium 5.3
A vulnerability exists in the handling of a malformed IEC 104 TCP packet. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected conne ...
Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connect…
-
Medium 5.5
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could caus…
-
Medium 5.3
A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i8…
-
Medium 5.5
Delta Electronics Delta Robot Automation Studio (DRAS) versions prior to 1.13.20 are affected by improper restrictions …
-
Medium 6.1
ISaGRAF Workbench Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') CWE-22
Rockwell Automation ISaGRAF Workbench software versions 6.0 through 6.6.9 are affected by a Path Traversal vulnerability. A crafted malicious .7z exchange file may allow an attacker to gain the privileges of the ISaGRAF Workbench software when opened. If the …
-
Medium 5.9
ABB Ability TM Operations Data Management Zenon Zenon Log Server file access control
Relative Path Traversal vulnerability in ABB Zenon 8.20 allows the user to access files on the Zenon system and user also can add own log messages and e.g., flood the log entries. An attacker who successfully exploit the vulnerability could access the Zenon r…
-
Medium 6.2
ABB Ability TM Operations Data Management Zenon Zenon Log Server file access control
Storing Passwords in a Recoverable Format vulnerability in ABB Zenon 8.20 allows an attacker who successfully exploit the vulnerability may add more network clients that may monitor various activities of the Zenon.
-
Medium 5.3
CODESYS Visualization vulnerable to user enumeration
All CODESYS Visualization versions before V4.2.0.0 generate a login dialog vulnerable to information exposure allowing a remote, unauthenticated attacker to enumerate valid users.
-
Medium 6.8
Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow…
-
Medium 6.5
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.15), Teamcenter V13.0 (All versions < V…
-
Medium 6.8
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.15), Teamcenter V13.0 (All versions < V…
-
Medium 5.3
A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license ser…
-
Medium 5.3
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions), CP-8000 MASTER MODULE W…
-
Medium 5.8
Rockwell Automation CompactLogix 5370 and ControlLogix 5570 Controllers Improper Input Validation
The connection establishment algorithm found in Rockwell Automation CompactLogix 5370 and ControlLogix 5570 versions 33 and prior does not sufficiently manage its control flow during execution, creating an infinite loop. This may allow an attacker to send spe…
-
Medium 5.0
HTTP Response Splitting in Hitachi Energy’s MSM Product
A vulnerability exists in the http web interface where the web interface does not validate data in an HTTP header. This causes a possible HTTP response splitting, which if exploited could lead an attacker to channel down harmful code into the user’s web brows…
-
Medium 5.0
Cross Site Request Forgery (CSRF) in Hitachi Energy’s MSM Product
A vulnerability exists in the HTTP web interface where the web interface does not sufficiently verify if a well-formed, valid, consistent request was intentionally provided by the user who submitted the request. This cause a Cross Site Request Forgery (CSRF),…
-
Medium 6.5
ICSA-22-188-01 Rockwell Automation MicroLogix Improper Restriction of Rendered UI Layers or Frames
The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in the HTTP response, which could allow clickjacking attacks.
-
Medium 5.5
A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware …
-
Medium 5.9
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could caus…
-
Medium 5.9
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized…
-
Medium 5.9
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that coul…
-
Medium 5.1
A CWE-20: Improper Input Validation vulnerability exists that could cause the device watchdog function to be disabled i…
-
Medium 6.7
A CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists where weak cipher suites can be used f…
-
Medium 6.8
A CWE-269: Improper Privilege Management vulnerability exists that could allow elevated functionality when guessing cre…
-
Medium 6.3
A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.7.3). The affected application uses …
-
Medium 5.5
Plaintext Storage of a password in CODESYS V3 OPC DA Server
The CODESYS OPC DA Server prior V3.5.18.20 stores PLC passwords as plain text in its configuration file so that it is visible to all authorized Microsoft Windows users of the system.
-
Medium 6.3
Use of hard-coded credentials vulnerability exists in STARDOM FCN Controller and FCJ Controller R4.10 to R4.31, which m…
-
Medium 4.8
A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms,…
-
Medium 6.5
CODESYS runtime system prone to denial of service due to buffer over read
Multiple CODESYS Products are prone to a buffer over read. A low privileged remote attacker may craft a request with an invalid offset, which can cause an internal buffer over-read, resulting in a denial-of-service condition. User interaction is not required.
-
Medium 6.5
CODESYS runtime system prone to denial of service due to buffer copy
Multiple CODESYS products are affected to a buffer overflow.A low privileged remote attacker may craft a request, which can cause a buffer copy without checking the size of the service, resulting in a denial-of-service condition. User Interaction is not requi…
-
Medium 6.5
CODESYS runtime system prone to denial of service due to out of bounds read
In multiple CODESYS products, a low privileged remote attacker may craft a request, which cause an out-of-bounds read, resulting in a denial-of-service condition. User Interaction is not required.