Category
ICS / OT
4,112 known vulnerabilities.
873 results · Clear filters · Feed
-
Medium 5.3
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethe…
-
Medium 6.5
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethe…
-
Medium 6.5
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethe…
-
Medium 6.5
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethe…
-
Medium 5.1
A vulnerability has been identified in LOGO! Soft Comfort (All versions < V8.4). A zip slip vulnerability could be trig…
-
Medium 6.5
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions…
-
Medium 5.5
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD…
-
Medium 6.5
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethe…
-
Medium 5.3
MOXA NPort IAW5000A-I/O Series
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows sensitive information to be displayed without proper authorization.
-
Medium 5.5
Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS: An attacker can use the knowledge gained by reading the insufficiently protected sensitive information to plan further attacks.
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use the knowledge gained by reading the insufficiently protected sensitive information to plan further attacks.
-
Medium 6.5
Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS: A specially crafted LLDP packet may lead to a high system load in the PROFINET stack.
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the PROFINET stack. An attacker can cause failure of system services or a complete reboot.
-
Medium 5.4
Phoenix Contact mGuard Devices versions before 8.8.3: LAN ports get functional after reboot even if they are disabled in the device configuration
On Phoenix Contact mGuard Devices versions before 8.8.3 LAN ports get functional after reboot even if they are disabled in the device configuration. For mGuard devices with integrated switch on the LAN side, single switch ports can be disabled by device confi…
-
Medium 6.5
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All ve…
-
Medium 4.3
Rockwell Automation FactoryTalk View SE
All versions of FactoryTalk View SE disclose the hostnames and file paths for certain files within the system. A remote, authenticated attacker may be able to leverage this information for reconnaissance efforts. Rockwell Automation recommends enabling built …
-
Medium 5.3
Beckhoff: Etherleak in TwinCAT RT network driver
Beckhoff's TwinCAT RT network driver for Intel 8254x and 8255x is providing EtherCAT functionality. The driver implements real-time features. Except for Ethernet frames sent from real-time functionality, all other Ethernet frames sent through the driver are n…
-
Medium 6.6
ABB System 800xA Inter process communication vulnerability - System 800xA Base
Insufficient protection of the inter-process communication functions in ABB System 800xA Base (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
-
Medium 6.6
ABB System 800xA Inter process communication vulnerability - 800xA RNRP
Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
-
Medium 5.3
ABB System 800xA Inter process communication vulnerability
Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system t…
-
Medium 5.3
ABB Central Licensing System - Denial of Service Vulnerability
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2…
-
Medium 5.3
ABB Central Licensing System - Elevation of Privilege Vulnerability
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2…
-
Medium 5.5
ABB System 800xA Weak File Permissions - different products
Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low p…
-
Medium 6.2
ABB/Busch-Jaeger Telephone Gateway TG/S 3.2 Information Exposure
The Configuration pages in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway for user profiles and services transfer the password in plaintext (although hidden when displayed).
-
Medium 6.2
ABB/Busch-Jaeger Telephone Gateway TG/S 3.2 Plaintext storing of credentials
The backup function in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway saves the current settings and configuration of the application, including credentials of existing user accounts and other configuration's credentials in plaintext.
-
Medium 6.3
ABB eSOMS X-XSS-Protection not enabled
For ABB eSOMS versions 4.0 to 6.0.2, the X-XSS-Protection HTTP response header is not set in responses from the web server. For older web browser not supporting Content Security Policy, this might increase the risk of Cross Site Scripting.
-
Medium 6.5
eSOMS X-FrameOption
For ABB eSOMS versions 4.0 to 6.0.2, the X-Frame-Options header is not configured in HTTP response. This can potentially allow 'ClickJacking' attacks where an attacker can frame parts of the application on a malicious web site, revealing sensitive user inform…
-
Medium 6.5
eSOMS Cachecontrol (Pragma) HTTP Header
For ABB eSOMS 4.0 to 6.0.3, the Cache-Control and Pragma HTTP header(s) have not been properly configured within the application response. This can potentially allow browsers and proxies to cache sensitive information.
-
Medium 5.9
ABB eSOMS: SSL medium strength Cipher Suites
ABB eSOMS versions 4.0 to 6.0.3 accept connections using medium strength ciphers. If a connection is enabled using such a cipher, an attacker might be able to eavesdrop and/or intercept the connection.
-
Medium 6.1
ABB eSOMS: REDIS clear text credentials
The Redis data structure component used in ABB eSOMS versions 6.0 to 6.0.2 stores credentials in clear text. If an attacker has file system access, this can potentially compromise the credentials' confidentiality.
-
Medium 5.4
ABB eSOMS: Stored XSS vulnerability
Lack of adequate input/output validation for ABB eSOMS versions 4.0 to 6.0.2 might allow an attacker to attack such as stored cross-site scripting by storing malicious content in the database.
-
Medium 6.5
ABB eSOMS: Password complexity issue
eSOMS versions 4.0 to 6.0.3 do not enforce password complexity settings, potentially resulting in lower access security due to insecure user passwords.
-
Medium 4.3
ABB eSOMS: HTTP response information leakage
For ABB eSOMS versions 4.0 to 6.0.3, HTTPS responses contain comments with sensitive information about the application. An attacker might use this detail information to specifically craft the attack.
-
Medium 6.1
eSOMS: X-Content-Type-Options Header Missing
For ABB eSOMS versions 4.0 to 6.0.3, the X-Content-Type-Options Header is missing in the HTTP response, potentially causing the response body to be interpreted and displayed as different content type other than declared. A possible attack scenario would be un…
-
Medium 5.3
ABB eSOMS: HTTPOnly flag not set
For ABB eSOMS versions 4.0 to 6.0.2, the HTTPOnly flag is not set. This can allow Javascript to access the cookie contents, which in turn might enable Cross Site Scripting.
-
Medium 6.8
A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0). The two FTP services (default …
-
Medium 6.5
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The DOWNLOADS section in th…
-
Medium 6.3
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The web interface of the Co…
-
Medium 5.3
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0), SiNVR/SiVMS Video Server (A…
-
Medium 4.3
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (…
-
Medium 6.1
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The web interface of the Co…
-
Medium 5.3
A vulnerability has been identified in SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200pro …