Medium 5.5
Beckhoff: XSS Vulnerability in TwinCAT 3 HMI Server
An high privileged remote attacker can inject arbitrary content into the custom CSS field on the affected devices due to improper neutralization of input during web page generation ('Cross-site Scripting').
-
Medium 6.5
Idle session timeout is not configured for multiple open ports
Insufficient Session Expiration vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K.
-
Medium 6.5
Improper implementation of Modbus protocol leading to DOS attack
Improper Check for Unusual or Exceptional Conditions vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K.
-
Medium 4.0
Modbus/TCP Dos Vulnerability in DVP15MC11T
Delta Electronics DVP15MC11T lacks proper validation of the modbus/tcp packets and can lead to denial of service.
-
Medium 5.1
Information Disclosure Vulnerability in GT Designer3
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GT Designer3 Version1 (GOT2000) all versions and Mitsubishi Electric GT Designer3 Version1 (GOT1000) all versions allows a local unauthenticated attacker to obtain plaintext crede…
-
Medium 6.3
Unauthenticated Device Registration Vulnerability in MXsecurity Series
An unauthenticated device registration vulnerability, caused by Improperly Controlled Modification of Dynamically-Determined Object Attributes, has been identified in the MXsecurity Series. An unauthenticated remote attacker can exploit this vulnerability by …
-
Medium 4.3
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected devices exposes server inf…
-
Medium 4.9
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected application exhibits incon…
-
Medium 4.6
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected device contains a USB port…
-
Medium 4.3
A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.10.1), RUGGEDCOM RS416Pv2 V5.X (All ve…
-
Medium 6.5
A vulnerability has been identified in SINEC Security Monitor (All versions < V4.10.0). The affected application lacks …
-
Medium 6.7
A vulnerability has been identified in SINEC Security Monitor (All versions < V4.10.0). The affected application does n…
-
Medium 4.3
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP4). Affected applications do…
-
Medium 6.3
A vulnerability has been identified in Gridscale X Prepay (All versions < V4.2.1). The affected application is vulnerab…
-
Medium 5.3
A vulnerability has been identified in Gridscale X Prepay (All versions < V4.2.1). The affected application is vulnerab…
-
Medium 4.3
Authenticated Denial-of-Service via SSH
A low privileged remote attacker can use the ssh feature to execute commands directly after login. The process stays open and uses resources which leads to a reduced performance of the management functions. Switching functionality is not affected.
-
Medium 4.6
Hardcoded User Password
An attacker can use an undocumented UART port on the PCB as a side-channel with the user hardcoded credentials obtained from CVE-2025-41692 to gain read access to parts of the filesystem of the device.
-
Medium 6.5
Authenticated Denial-of-Service via Webshell
A low privileged remote attacker can run the webshell with an empty command containing whitespace. The server will then block until it receives more data, resulting in a DoS condition of the websserver.
-
Medium 6.8
Weak/Predictable root Password
A high privileged remote attacker with admin privileges for the webUI can brute-force the "root" and "user" passwords of the underlying OS due to a weak password generation algorithm.
-
Medium 6.8
Shell access to UART Console
An attacker can use an undocumented UART port on the PCB as a side-channel to get root access e.g. with the credentials obtained from CVE-2025-41692.
-
Medium 5.9
CODESYS Control - Linux/QNX SysSocket flaw
An unauthenticated remote attacker, who beats a race condition, can exploit a flaw in the communication servers of the CODESYS Control runtime system on Linux and QNX to trigger an out-of-bounds read via crafted socket communication, potentially causing a den…
-
Medium 6.1
Stack Memory Corruption Vulnerability
Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
-
Medium 5.5
Information Disclosure Vulnerability in GX Works2
Cleartext Storage of Sensitive Information Vulnerability in GX Works2 all versions allows an attacker to disclose credential information stored in plaintext from project files. As a result, the attacker may be able to open project files protected by user auth…
-
Medium 5.7
A vulnerability has been identified in Mendix RichText (All versions >= V4.0.0 < V4.6.1). Affected widget does not prop…
-
Medium 6.9
CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on…
-
Medium 6.5
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (…
-
Medium 5.5
A vulnerability has been identified in Altair Grid Engine (All versions < V2026.0.0). Affected products do not properly…
-
Medium 4.7
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application …
-
Medium 5.3
Smallworld SWMFS Arbitrary File Ops
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in GE Vernova Smallworld on Windows, Linux allows File Manipulation.This issue affects Smallworld: 5.3.5. and previous versions.
-
Medium 5.3
Denial-of-Service(DoS) Vulnerability in TCP Communication Function on MELSEC iQ-F Series CPU module
Improper Validation of Specified Quantity in Input vulnerability in TCP Communication Function on Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote attacker to disconnect the connection by sending specially crafted TCP packets to c…
-
Medium 6.1
BSS(Block Started by Symbol) Memory Corruption Vulnerability
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
-
Medium 6.8
Inadequate access control measure allows unauthorized users to access restricted administrative functions
Honeywell S35 Series Cameras contains an authorization bypass Vulnerability through User controller key. An attacker could potentially exploit this vulnerability, leading to Privilege Escalation to admin privileged functionalities . Honeywell also recommends …
-
Medium 4.8
Cross-site Scripting has been identified in Moxa’s Ethernet switches, which allows an authenticated administrative atta…
-
Medium 6.8
Heap Memory Corruption Vulnerability
Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (MID/ CE) -Terra AC MID, ABB Terra AC wallbox (MID/ CE) -Terra AC Juno CE, ABB Terra AC wallbox (MID/ CE) -Terra AC PTB, ABB Terra …
-
Medium 5.3
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and ro…
-
Medium 4.4
A vulnerability has been identified in SiPass integrated (All versions < V3.0). Affected server applications store user…
-
Medium 5.3
Phoenix Contact: WebSocket Handler Denial of Service
The websocket handler is vulnerable to a denial of service condition. An unauthenticated remote attacker can send a crafted websocket message to trigger the issue without affecting the core functionality.
-
Medium 5.3
Phoenix Contact: Webserver Denial of Service through Malformed Content-Length
The webserver is vulnerable to a denial of service condition. An unauthenticated remote attacker can craft a special GET request with an over-long content-length to trigger the issue without affecting the core functionality.
-
Medium 6.8
Phoenix Contact: WebSocket Message Interception Leaks Webfrontend Credentials
An unauthenticated remote attacker (MITM) can intercept the websocket messages to gain access to the login credentials for the Webfrontend.
-
Medium 5.3
Phoenix Contact: Unauthenticated Modbus Service DoS via Crafted Function Code
An unauthanticated remote attacker can perform a DoS of the Modbus service by sending a specific function and sub-function code without affecting the core functionality.