High 7.8
Delta Electronics ASDA-Soft Out-of-bounds Write
ASDA-Soft: Version 5.4.1.0 and prior does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds write condition.
-
High 7.8
Delta Electronics ASDA-Soft Out-of-bounds Read
ASDA-Soft: Version 5.4.1.0 and prior does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds read condition.
-
Unscored —
OS command injection vulnerability exists in CENTUM VP R4.01.00 to R4.03.00, CENTUM VP Small R4.01.00 to R4.03.00, CENT…
-
Unscored —
Improper authentication vulnerability in the communication protocol provided by AD (Automation Design) server of CENTUM…
-
Medium 5.3
An information disclosure vulnerability exists in the Web Application functionality of Moxa MXView Series 3.2.4. Networ…
-
Critical 10.0
An authentication bypass vulnerability exists in the Web Application functionality of Moxa MXView Series 3.2.4. A speci…
-
Unscored —
A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.2). The affected application contains an…
-
Unscored —
A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.2). The affected application contains an…
-
Unscored —
A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.2). The affected application contains an…
-
Unscored —
A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions < V3.0.0), SCALANCE W1788-2 EEC M12 (All vers…
-
Unscored —
A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions < V3.0.0), SCALANCE W1788-2 EEC M12 (All vers…
-
Unscored —
A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions < V3.0.0), SCALANCE W1788-2 EEC M12 (All vers…
-
Unscored —
A vulnerability has been identified in SICAM A8000 CP-8031 (All versions < V4.80), SICAM A8000 CP-8050 (All versions < …
-
Unscored —
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Application…
-
Unscored —
A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions < V3.1 SP1), SINETPLAN (A…
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
Unscored —
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.27), Mendix Application…
-
Unscored —CVE-2022-23450 EPSS 36%
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Mana…
-
Unscored —
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Mana…
-
Unscored —
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Mana…
-
Unscored —
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 …
-
High 7.5
A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (A…
-
Medium 5.3
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP …
-
Critical 10.0
ICSA-22-090-05 Rockwell Automation Logix Controllers
An attacker with the ability to modify a user program may change user program code on some ControlLogix, CompactLogix, and GuardLogix Control systems. Studio 5000 Logix Designer writes user-readable program code to a separate location than the executed compil…
-
High 7.5
Special HTTP(s) Requests can cause a buffer-read causing a crash of the webserver and the runtime system.
A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtime system.
-
Medium 6.5
A bug in the CODESYS V3 CmpUserMgr component fails to correctly apply a security policy.
A bug in CmpUserMgr component can lead to only partially applied security policies. This can result in enabled, anonymous access to components part of the applied security policy.
-
High 7.5
Communication Components in multiple CODESYS products vulnerable to communication channel disruption
An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed.
-
High 7.8
CODESYS driver SysDrv3S allows SYSTEM users on Microsoft Windows to read and write in restricted memory space.
The SysDrv3S driver in the CODESYS Control runtime system on Microsoft Windows allows any system user to read and write within restricted memory space.
-
High 8.1
A component of the CODESYS Control runtime system allows read and write access to configuration files
A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products.
-
High 7.1
Untrusted Pointer Dereference in multiple CODESYS products can lead to a DoS.
An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor cont…
-
Medium 6.5
Null Pointer Dereference in multiple CODESYS products can lead to a DoS.
An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash.
-
High 7.8
Rockwell Automation Studio 5000 Logix Designer Code Injection
Omron CX-Position (versions 2.5.3 and prior) is vulnerable to multiple stack-based buffer overflow conditions while parsing a specific project file, which may allow an attacker to locally execute arbitrary code.