Skip to content
OpenAdvisories

Source

CISA ICS & IT advisories

Source: https://www.cisa.gov/news-events/cybersecurity-advisories

1,185 results · Clear filters · Feed

  • Critical max 9.8
    ICSA-24-268-06 1 CVE rev. 2

    OMNTEC Proteus Tank Monitoring (Update A)

    Successful exploitation of this vulnerability allow an attacker to perform administrative actions without proper authentication.

    first Sep 24, 2024
  • Critical max 8.8
    ICSA-24-270-04 10 CVEs rev. 2

    goTenna Pro X and Pro X2 (Update A)

    Successful exploitation of these vulnerabilities could allow an attacker to compromise the confidentiality and integrity of the communications between the affected devices.

    first Sep 26, 2024
  • Critical max 9.8

    Kieback&Peter DDC4000 Series

    Successful exploitation of these vulnerabilities could allow an unauthenticated attacker to gain full administrator rights on the system.

  • Critical max 7.8

    Rockwell Automation DataMosaix Private Cloud

    Successful exploitation of these vulnerabilities could cause a denial-of-service condition, view customer data, or perform remote code execution.

  • Critical max 9.8
    ICSA-22-286-13 3 CVEs rev. 4

    Siemens LOGO! 8 BM Devices

    LOGO! 8 BM (incl. SIPLUS variants) contains multiple web-related vulnerabilities. These could allow an attacker to execute code remotely, put the device into a denial of service state or retrieve parts of the memory. The vulnerabilities are related to the har…

    first Oct 11, 2022
  • Critical max 9.8

    Siemens SENTRON PAC3200 Devices

    SENTRON PAC3200 only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface could easily bypass this protection by brute-force attacks or by monitoring the Modbus cleartext commu…

  • Critical max 9.8

    Schneider Electric System Monitor Application in Harmony and Pro-face PS5000 Legacy Industrial PCs

    Schneider Electric is aware of a vulnerability in its System Monitor application of Harmony Industrial PC Series and Pro-face PS5000 trusted Legacy industrial PC Series product(s). The Harmony Industrial PC Series and Pro-face PS5000 legacy industrial PC Seri…

  • Critical max 9.3

    TEM Opera Plus FM Family Transmitter

    Successful exploitation of these vulnerabilities could allow an attacker to perform remote code execution.

    TEM
  • Critical max 9.8

    Delta Electronics DIAEnergie

    Successful exploitation of these vulnerabilities could allow an attacker to retrieve records or cause a denial of service.

  • Critical max 9.8

    Optigo Networks ONS-S8 - Spectra Aggregation Switch

    Successful exploitation of these vulnerabilities could allow an attacker to achieve remote code execution, arbitrary file upload, or bypass authentication.

  • Critical max 9.3

    Atelmo Atemio AM 520 HD Full HD Satellite Receiver

    Successful exploitation of this vulnerability could allow an unauthorized attacker to execute system commands with elevated privileges.

  • Critical
    ICSA-19-274-01 11 CVEs rev. 6

    Interpeak IPnet TCP/IP Stack (Update E)

    Successful exploitation of these vulnerabilities could allow remote code execution.

    first Oct 1, 2019
  • Critical max 9.8

    OPW Fuel Management Systems SiteSentinel

    Successful exploitation of this vulnerability could allow an attacker to bypass authentication and obtain full administrative privileges to the server.

  • Critical max 9.4

    Alisonic Sibylla

    Successful exploitation of this vulnerability could result in an attacker obtaining device information from the database, dumping credentials, or potentially gaining administrator access.

  • Critical max 10.0

    Dover Fueling Solutions ProGauge MAGLINK LX CONSOLE

    Successful exploitation of these vulnerabilities could allow a remote attacker to gain full control of the system.

  • Critical max 9.8
    ICSA-20-168-01 19 CVEs 1 exploited rev. 10

    Treck TCP/IP (Update I)

    Successful exploitation of these vulnerabilities may allow remote code execution or exposure of sensitive information.

    first Jun 16, 2020
  • Critical max 9.8

    Rockwell Automation FactoryTalk View Site

    Successful exploitation of this vulnerability could allow an attacker to perform unauthenticated remote code execution.

  • Critical max 9.9
    VA-24-254-01 3 CVEs rev. 2

    IBM webMethods Integration Multiple Vulnerabilities

    IBM webMethods Integration contains multiple vulnerabilities that could allow an authenticated attacker to escalate privileges within webMethods, execute arbitrary operating system commands, or read arbitrary files.

    IBM
  • Critical max 6.3

    Viessmann Climate Solutions SE Vitogate 300

    Successful exploitation of these vulnerabilities could allow an attacker to achieve remote code execution.

  • Critical max 8.6

    Siemens SINEMA

    SINEMA Remote Connect Client before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.

  • Critical max 10.0

    Siemens Industrial Edge Management

    Industrial Edge Management contains an Authorization Bypass vulnerability that could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system. Siemens has released new versions for the affected products and recommends to u…

  • Critical max 9.8

    FESTO Didactic CP, MPS 200, and MPS 400 Firmware

    Siemens SIMATIC S7-1200 and S7-1500 CPUs contained in various Festo Didactic products contain a memory protection bypass vulnerability that could allow an attacker to write arbitrary data and code to protected memory areas or read sensitive data to launch fur…

  • Critical max 10.0

    Baxter Connex Health Portal

    Successful exploitation of these vulnerabilities could lead to malicious code injection, shutdown of database service, or the ability to access, modify, or delete sensitive data from the database.

  • Critical max 9.3

    Rockwell Automation ThinManager ThinServer

    Successful exploitation of these vulnerabilities could allow an attacker to read arbitrary files and execute arbitrary code with system privileges.

  • Critical max 9.8

    Rockwell Automation AADvance Standalone OPC-DA Server

    Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code in the affected product.

  • Critical max 8.6

    Rockwell Automation DataMosaix Private Cloud

    Successful exploitation of this vulnerability could allow an attacker to generate cookies for a user ID without the use of a username or password, resulting in the malicious actor to take over the account.

  • Critical max 9.8
    ICSA-23-320-03 3 CVEs rev. 2

    Siemens Desigo CC product family

    Versions V5.0 through V7 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS), as well as the Desigo CC-based SENTRON powermanager, are affected by multiple vulnerabilities in the underlying third-party component WIB…

    first Nov 14, 2023
  • Critical max 9.1
    ICSA-23-348-14 7 CVEs rev. 2

    Siemens RUGGEDCOM and SCALANCE M-800/S615 Family

    SCALANCE M-800 family before V8.0 is affected by multiple vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or…

    first Dec 12, 2023
  • Critical max 9.1
    ICSA-24-228-06 29 CVEs 1 exploited

    Siemens SINEC NMS

    SINEC NMS before V3.0 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC NMS and recommends to update to the latest version.

  • Critical max 10.0

    Vonets WiFi Bridges

    Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information, cause a denial-of-service condition, or execute arbitrary code on the affected device.

  • Critical max 9.8

    Siemens SICAM Products

    Multiple SICAM products are affected by unauthorized password reset and firmware downgrade vulnerabilities that could lead to privilege escalation and potential leak of information, namely: - SICAM A8000 Device firmware - CPCI85 for CP-8031/CP-8050 - SICAM EG…

  • Critical max 9.3

    Rockwell Automation ThinManager ThinServer

    Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code or cause a denial-of-service condition.

  • Critical max 9.3
    ICSA-23-269-03 1 CVE rev. 2

    Mitsubishi Electric FA Engineering Software (Update A)

    Successful exploitation of this vulnerability could allow a local attacker to execute code, which could result in information disclosure, tampering with and deletion of information, or a denial-of-service (DoS) condition.

    first Sep 26, 2023
  • Critical max 9.8
    ICSA-22-167-17 29 CVEs rev. 2

    Siemens OpenSSL Affecting Industrial Products

    SINEMA Remote Connect Server is affected by multiple vulnerabilities, including - A cross-site scripting vulnerability in an error message pop up window (CVE-2022-29034) - Several authentication bypass, privilege escalation and integrity check vulnerabilities…

    first Jun 14, 2022
  • Critical max 10.0
    ICSA-24-116-03 1 CVE 1 exploited rev. 2

    Siemens RUGGEDCOM APE1808 devices configured with Palo Alto Networks Virtual NGFW

    Palo Alto Networks has published [1] information on CVE-2024-3400 in PAN-OS. This advisory addresses Siemens Industrial products affected by this vulnerability. Siemens has released a new version of Palo Alto Networks Virtual NGFW for RUGGEDCOM APE1808 and re…

    first Apr 19, 2024
  • Critical max 7.8
    ICSA-24-165-06 32 CVEs rev. 2

    Siemens TIM 1531 IRC

    Siemens has released new versions for the affected products and recommends to update to the latest versions.

    first Jun 11, 2024
  • Critical max 9.8
    ICSA-25-107-02 6 CVEs rev. 3

    Schneider Electric Sage Series

    Schneider Electric is aware of multiple vulnerabilities in its SAGE RTU products. The SAGE RTU products are hardware devices that collect utility substation information from different devices and passes it along to a SCADA software platform. Failure to apply …

    first Jun 11, 2024
  • Critical max 9.6
    ICSA-24-193-01 13 CVEs

    Siemens Remote Connect Server

    SINEMA Remote Connect Server before V3.2 SP1 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Server and recommends to update to the latest version.

  • Critical max 10.0
    ICSA-24-177-02 1 CVE rev. 2

    PTC Creo Elements/Direct License Server (Update A)

    Successful exploitation of this vulnerability could allow unauthenticated remote attackers to execute arbitrary OS commands.

    PTC
    first Jun 25, 2024
  • Critical max 9.1
    ICSA-24-179-04 1 CVE rev. 2

    Johnson Controls Illustra Essentials Gen 4 (Update A)

    Successful exploitation of this vulnerability could allow an attacker to inject commands.

    first Jun 27, 2024