Skip to content
OpenAdvisories

Source

CISA ICS & IT advisories

Source: https://www.cisa.gov/news-events/cybersecurity-advisories

1,185 results · Clear filters · Feed

  • Critical max 9.9

    Johnson Controls Software House C-CURE 9000 and American Dynamics victor VMS

    Successful exploitation of this vulnerability may allow an attacker to access credentials used for access to the application.

  • Critical max 10.0

    Emerson OpenEnterprise

    Successful exploitation of these vulnerabilities could allow an attacker access to OpenEnterprise configuration services or access passwords for OpenEnterprise user accounts.

  • Critical

    Opto 22 SoftPAC Project

    Successful exploitation of these vulnerabilities could allow arbitrary file write access with system access, start or stop service, allow remote code execution, and limit system availability.

  • Critical max 10.0

    Emerson WirelessHART Gateway

    Successful exploitation of this vulnerability could disable the internal gateway firewall. Once the gateway's firewall is disabled, a malicious user could issue specific commands to the gateway, which could then be forwarded on to the end user's wireless devi…

  • Critical

    Advantech WebAccess Node

    Successful exploitation of these vulnerabilities may allow information disclosure, remote code execution, and compromise system availability.

  • Critical

    SAE IT-systems FW-50 Remote Telemetry Unit (RTU)

    Successful exploitation of these vulnerabilities could allow an attacker to execute remote code through input injection, or allow an attacker to view the file structure of the affected device and access files that should be inaccessible.

  • Critical max 8.8
    ICSA-19-122-03 6 CVEs 1 exploited rev. 3

    Sierra Wireless AirLink ALEOS (Update B)

    Successful exploitation of these vulnerabilities could allow attackers to remotely execute code, discover user credentials, upload files, or discover file paths.

    first May 2, 2019
  • Critical

    Inductive Automation Ignition

    Successful exploitation of this vulnerability could allow an attacker to write endless log statements into the database, which could result in a denial-of-service condition.

  • Critical

    Triangle MicroWorks SCADA Data Gateway

    These vulnerabilities allow remote attackers to execute arbitrary code and disclose on affected installations of Triangle Microworks SCADA Data Gateway with DNP3 Outstation channels. Authentication is not required to exploit these vulnerabilities.

  • Critical

    Siemens TIM 3V-IE and 4R-IE Family Devices

  • Critical
    ICSA-20-042-01 6 CVEs rev. 2

    Synergy Systems & Solutions HUSKY RTU (Update A)

    Successful exploitation of these vulnerabilities could allow an attacker to read sensitive information, execute arbitrary code, or cause a denial-of-service condition.

    first Feb 11, 2020
  • Critical

    Advantech WebAccess/NMS

    Successful exploitation of these vulnerabilities may allow an attacker to gain remote code execution, upload files, delete files, cause a denial-of-service condition, and create an admin account for the application.

  • Critical

    Hirschmann Automation and Control HiOS and HiSecOS Products

    Successful exploitation of this vulnerability could allow an unauthenticated, remote attacker to overflow a buffer and fully compromise the device.

  • Critical max 9.8

    ICSA-20-070-04_Johnson Controls Kantech EntraPass

    Joachim Kerschbaumer reported this vulnerability to Johnson Controls.

  • Critical max 9.8

    Rockwell Automation MicroLogix Controllers and RSLogix 500 Software

    Successful exploitation of these vulnerabilities could allow an attacker to gain access to sensitive project file information including passwords.

  • Critical

    WAGO I/O-CHECK

    Successful exploitation of these vulnerabilities could allow an attacker to change settings, delete the application, run remote code, cause a system crash, cause a denial-of-service condition, revert to factory settings, and overwrite MAC addresses.

  • Critical

    ICSA-20-063-02_PHOENIX CONTACT Emalytics Controller ILC

    Phoenix Contact strongly recommends affected users update to engineering software Emalytics v1.2.3 or higher and recommission the controllers. The updated version is available on the vendor's product page.

  • Critical max 9.9
    ICSA-20-063-04 12 CVEs

    Moxa AWK-3131A Series Industrial AP/Bridge/Client

    Successful exploitation of these vulnerabilities could allow an attacker to gain control of the device and remotely execute arbitrary code.

  • Critical max 9.8

    Moxa MB3xxx Series Protocol Gateways

    Successful exploitation of these vulnerabilities could crash the device, cause a buffer overflow, allow remote execution of arbitrary code, or allow access to sensitive information.

  • Critical

    Moxa PT-7528 and PT-7828 Series Ethernet Switches

    Successful exploitation of these vulnerabilities could crash the device or allow access to sensitive information.

  • Critical

    Moxa EDS-G516E and EDS-510E Series Ethernet Switches

    Successful exploitation of these vulnerabilities could crash the device, execute arbitrary code, and allow access to sensitive information.

  • Critical max 9.4

    ICSA-20-051-01_B&R Automation Studio and Automation Runtime

    Yehuda Anikster and Amir Preminger of Claroty reported this vulnerability to CISA.

  • Critical

    Rockwell Automation FactoryTalk Diagnostics

    This updated advisory is a follow-up to the original advisory titled ICSA-20-051-02-Rockwell Automation FactoryTalk Diagnostics that was published February 20, 2020, on the ICS webpage on cisa.gov/ICS.

  • Critical

    Honeywell NOTI-FIRE-NET Web Server (NWS-3)

    Successful exploitation of these vulnerabilities could result in an attacker bypassing web server authentication methods.

  • Critical max 9.4

    Auto-Maskin RP210E, DCU210E, and Marine Observer Pro (Android App)

    Successful exploitation of these vulnerabilities could allow a remote attacker to gain root access to the underlying operating system of the device and may allow read/write access.

  • Critical max 9.8
    ICSMA-20-049-01 1 CVE 1 exploited

    Spacelabs Xhibit Telemetry Receiver (XTR)

    A remote code execution vulnerability called BlueKeep (CVE-2019-0708) exists within the Remote Desktop Protocol (RDP) used by the Microsoft Windows operating systems listed below. An attacker can exploit this vulnerability to perform remote code execution on …

  • Critical

    Siemens SIMATIC CP 1543-1

  • Critical
    ICSA-18-088-02 1 CVE rev. 2

    Siemens TIM 1531 IRC

    first Mar 27, 2018
  • Critical
    ICSA-18-352-05 1 CVE rev. 4

    Siemens TIM 1531 IRC Modules

    first Dec 11, 2018
  • Critical

    ICSA-20-035-01_AutomationDirect C-More Touch Panels

    Joel Langill of Amentum Mission Engineering & Resilience reported this vulnerability to CISA.

  • Critical

    GE CARESCAPE, ApexPro, and Clinical Information Center systems

    Successful exploitation of these vulnerabilities could occur when an attacker gains access to the mission critical (MC) and/or information exchange (IX) networks due to improper configuration or physical access to devices. An exploit could result in a loss of…

  • Critical

    ICSA-20-021-01_Honeywell Maxpro VMS & NVR

    Joachim Kerschbaumer discovered these vulnerabilities; Honeywell reported these vulnerabilities to CISA.

  • Critical

    Siemens SINEMA Server

  • Critical
    ICSMA-19-274-01 11 CVEs rev. 5

    Interpeak IPnet TCP/IP Stack (Update D)

    Successful exploitation of these vulnerabilities could allow remote code execution.

    first Oct 1, 2019
  • Critical

    Equinox Control Expert

    Successful exploitation of this vulnerability may allow remote code execution.

  • Critical

    Advantech DiagAnywhere Server

    Successful exploitation of this vulnerability may allow remote code execution.

  • Critical max 9.8

    Weidmueller Industrial Ethernet Switches

    Successful exploitation of these vulnerabilities could allow a remote attacker to gain unauthorized access to the device, affecting the confidentiality, integrity, and availability of the device the attacker is targeting.

  • Critical
    ICSA-19-337-02 14 CVEs

    Moxa AWK-3121

    Successful exploitation of these vulnerabilities could allow an attacker to view sensitive information, cause availability issues, and execute remote code.

  • Critical

    ABB Relion 670 Series

    Successful exploitation of this vulnerability may allow an attacker to read and delete files on the device.

    ABB
  • Critical

    Flexera FlexNet Publisher

    These vulnerabilities could allow an attacker to deny the acquisition of a valid license for legal use of the product. The memory corruption vulnerability could allow remote code execution.