  • Critical max 9.1
    ICSA-22-333-05 10 CVEs rev. 4

    Mitsubishi Electric FA Engineering Software (Update C)

    Successful exploitation of these vulnerabilities could allow unauthorized users to gain access to the MELSEC iQ-R/F/L series CPU modules and the MELSEC iQ-R series OPC UA server module or to view and execute programs or view project files without permissions.

    first Dec 5, 2022
  • High max 7.1

    Rockwell Automation Arena Simulation

    Successful exploitation of this vulnerability could allow local attackers to execute arbitrary code on affected installations of Arena.

  • Critical max 10.0

    Zenitel TCIV-3+

    Successful exploitation of these vulnerabilities could result in arbitrary code execution or cause a denial-of-service condition.

  • Critical max 9.8

    Festo Compact Vision System, Control Block, Controller, and Operator Unit products

    Successful exploitation of these vulnerabilities could result in an attacker accessing devices without authentication or modifying configuration files.

  • Critical max 8.8

    SiRcom SMART Alert (SiSA)

    Successful exploitation of this vulnerability could enable an attacker to remotely activate or manipulate emergency sirens.

  • High max 7.6

    Opto 22 groov View

    Successful exploitation of this vulnerability could result in credential exposure, key exposure, and privilege escalation.

  • Critical max 8.6

    Automated Logic WebCTRL Premium Server

    Successful exploitation of these vulnerabilities could allow a remote attacker to deceive a legitimate user into running malicious scripts or redirecting them to malicious websites.

  • Critical max 9.8

    Emerson Appleton UPSMON-PRO

    Successful exploitation of this vulnerability could allow remote attackers to execute arbitrary code on affected installations of Appleton UPSMON-PRO.

  • Medium max 6.8

    ICAM365 CCTV Camera Multiple Models

    Successful exploitation of these vulnerabilities could result in unauthorized exposure of camera video streams and camera configuration data.

  • Medium max 6.2

    Opto 22 GRV-EPIC and groov RIO

    Successful exploitation of this vulnerability could result in the execution of arbitrary shell commands with root privileges.

  • Critical max 9.8

    METZ CONNECT EWIO2

    A critical authentication bypass in EWIO-2 allows unauthenticated attackers with network access to gain administrative control over the device. Once compromised, an attacker can change configurations, manipulate data, disrupt services, and potentially render …

  • High max 8.3

    Shelly Pro 4PM

    Successful exploitation of this vulnerability could result in a denial-of-service condition.

  • High max 8.3

    Shelly Pro 3EM

    Successful exploitation of this vulnerability could result in a denial-of-service condition.

  • Critical max 9.8
    ICSA-25-273-04 33 CVEs rev. 2

    Festo Controller CECC-S,-LK,-D Family Firmware (Update A)

    Successful exploitation of these vulnerabilities could allow an attacker to crash services, escalate privileges, bypass authentication, or gain unauthorized access to sensitive systems and data.

    first Sep 30, 2025
  • Medium max 5.3

    Mitsubishi Electric MELSEC iQ-F Series

    Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the product.

  • Medium max 6.9

    AVEVA Application Server IDE

    Successful exploitation of this vulnerability could allow an attacker to tamper with help files and inject cross-site scripting (XSS) code.

  • High max 8.4

    AVEVA Edge

    Successful exploitation of this vulnerability could allow a local attacker to reverse engineer passwords through brute force.

  • Critical max 8.4

    Rockwell Automation Verve Asset Manager

    Successful exploitation of this vulnerability could result in an attacker accessing or altering user data.

  • High max 8.9

    Rockwell Automation Studio 5000 Simulation Interface

    Successful exploitation of these vulnerabilities could allow attackers to trigger outbound SMB requests to capture NTLM hashes and execute scripts with Administrator privileges upon system reboot.

  • High max 8.6

    Rockwell Automation FactoryTalk DataMosaix Private Cloud

    Successful exploitation of these vulnerabilities could allow an attacker to take over accounts, steal credentials, redirect users to a malicious website, or bypass MFA.

  • Critical max 10.0

    General Industrial Controls Lynx+ Gateway

    Successful exploitation of these vulnerabilities could result in obtaining sensitive device information, unauthorized access, or create a denial-of-service condition.

  • High max 7.5

    Rockwell Automation FactoryTalk Policy Manager

    Successful exploitation of this vulnerability could lead to resource exhaustion and denial of service.

  • High max 9.1

    *Rockwell Automation AADvance-Trusted SIS Workstation *

    Successful exploitation of this vulnerability may allow remote code execution.

  • Medium max 5.5

    Siemens SICAM P850 family and SICAM P855 family

    Successful exploitation of these vulnerabilities could allow an attacker to perform arbitrary actions on the device on behalf of a legitimate user, or impersonate that user.

  • High max 8.8

    Siemens Spectrum Power 4

    Successful exploitation of these vulnerabilities could allow an attacker to remotely execute code as application administrator or locally execute code as operating system administrator.

  • High max 8.7
    ICSA-25-224-03 5 CVEs rev. 3

    Schneider Electric EcoStruxure Power Monitoring Expert

    Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure Power Monitoring Expert (PME) and EcoStruxure Power Operation (EPO) and EcoStruxure Power SCADA Operation (PSO) products. EcoStruxure Power Monitoring Expert (PME) is an on-premises so…

    first Aug 12, 2025
  • High max 8.4

    Schneider Electric EcoStruxure Machine SCADA Expert & Pro-face BLUE Open Studio

    Schneider Electric is aware of a vulnerability disclosed on AVEVA component used in EcoStruxure Machine SCADA Expert and Pro-face BLUE Open Studio products. The EcoStruxure Machine SCADA Expert is software for developing HMI, SCADA, OEE and Dashboard projects…

  • High max 7.3

    Schneider Electric PowerChute Serial Shutdown

    Schneider Electric is aware of a vulnerability in its PowerChute™ Serial Shutdown product. The [PowerChute™ Serial Shutdown](https://www.se.com/us/en/product-range/137943580-powerchute-serial-shutdown/#products) product is a UPS management software enabling g…

  • Critical max 9.8
    ICSA-22-167-08 4 CVEs rev. 2

    Siemens SICAM GridEdge

    Multiple vulnerabilities were identified in the web server of the SICAM GridEdge application which includes missing authentication for critical API functions, absent cross-origin resource sharing restrictions and access to credentials. Siemens has released a …

    first Jun 14, 2022
  • Medium max 6.3
    ICSA-22-195-02 1 CVE rev. 2

    Siemens SICAM GridEdge

    SICAM GridEdge contains an improper access control vulnerability. This could allow persons with local access to the host system to inject an SSH key. Siemens has released a new version for SICAM GridEdge (Classic) and recommends to update to the latest versio…

    first Jul 12, 2022
  • Medium max 5.3
    ICSA-22-349-11 1 CVE rev. 6

    Siemens SIPROTEC 5 Devices

    Devices of the SIPROTEC 5 family contain a vulnerability related to secure client-initiated renegotiation. This could allow an unauthenticated attacker to cause a denial of service condition for the duration of the attack. Siemens has released new versions fo…

    first Dec 13, 2022
  • High max 7.5
    ICSA-23-103-06 1 CVE rev. 6

    Siemens SIPROTEC 5 Devices

    SIPROTEC 5 devices contain a null pointer dereference vulnerability in the web service. This could allow an attacker to send unauthenticated maliciously crafted http request that could cause denial of service condition of the device. Siemens has released new …

    first Apr 11, 2023
  • High max 7.5
    ICSA-23-257-01 1 CVE rev. 16

    Siemens SIMATIC, SIPLUS Products

    The OPC UA implementations (ANSI C and C++) as used in several SIMATIC products contain a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. S…

    first Sep 12, 2023
  • Medium max 5.9
    ICSA-24-193-14 1 CVE rev. 3

    Siemens SIPROTEC

    The SIPROTEC 5 devices are supporting weak encryption. This could allow an unauthorized attacker in a man-in-the-middle position to read any data passed over the connection between legitimate clients and the affected device. Siemens has released new versions …

    first Jul 9, 2024
  • Medium max 6.5
    ICSA-25-016-04 1 CVE rev. 4

    Siemens SIPROTEC 5 Products

    Affected SIPROTEC 5 devices do not properly limit the access of the web server to the filesystem. This could allow an authenticated remote attacker to read arbitrary files or the entire filesystem of the device. Siemens has released new versions for the affec…

    first Jan 14, 2025
  • Medium max 6.8
    ICSA-25-044-04 1 CVE rev. 3

    Siemens SIPROTEC 5

    Affected SIPROTEC 5 devices contain a development shell which is accessible via a physical interface which is not properly restricted. This could allow an unauthenticated attacker with physical access to an affected device to execute arbitrary commands on the…

    first Feb 11, 2025
  • Critical max 9.9
    ICSA-25-135-17 4 CVEs rev. 3

    Siemens RUGGEDCOM ROX II

    The web interface of RUGGEDCOM ROX II devices contain multiple Client-Side Enforcement of Server-Side Security vulnerabilities that could allow an attacker with a legitimate, highly privileged account on the web interface to get privileged code execution in t…

    first May 13, 2025
  • High max 7.6

    Siemens LOGO! 8 BM Devices

    LOGO! 8 BM (incl. SIPLUS variants) contains multiple vulnerabilities. These could allow an attacker to execute code remotely, put the device into a denial of service state, or change the behavior of the device. Siemens is preparing fix versions and recommends…

  • High max 7.5

    Siemens Solid Edge

    Solid Edge is affected by improper certificate validation while connecting to License Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks. Siemens has released a new version for Solid Edge SE2025 and reco…

  • Critical max 9.4

    Siemens COMOS

    COMOS is affected by two vulnerabilities that could allow an attacker to execute arbitrary code or lead to data infiltration. Siemens has released a new version for COMOS and recommends to update to the latest version.