  • Critical max 9.1
    ICSA-23-348-14 7 CVEs rev. 2

    Siemens RUGGEDCOM and SCALANCE M-800/S615 Family

    SCALANCE M-800 family before V8.0 is affected by multiple vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or…

    first Dec 12, 2023
  • High max 7.8
    ICSA-24-165-08 3 CVEs rev. 2

    Siemens Teamcenter Visualization and JT2Go

    Teamcenter Visualization and JT2Go are affected by out of bounds read, stack exhaustion and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the…

    first Jun 11, 2024
  • High max 7.8
    ICSA-24-193-03 1 CVE rev. 2

    Siemens Teamcenter Visualization and JT2Go

    Siemens Teamcenter Visualization and JT2Go are affected by an out of bounds read vulnerability in the APDFL library from Datalogics. If a user is tricked to open a malicious PDF file with the affected products, this could lead the application to crash or pote…

    first Jul 9, 2024
  • High max 7.2

    Siemens SCALANCE M-800, RUGGEDCOM RM1224

    SCALANCE M-800 family before V8.1 is affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • High max 8.7

    Siemens INTRALOG WMS

    INTRALOG WMS before V4 is affected by vulnerabilities in the SQL Client-Server communication and in the .NET framework. Successful exploitation could allow an unauthenticated attacker located in the INTRALOG WMS network to decrypt and modify client-server com…

  • High max 7.8

    Siemens Teamcenter Visualization and JT2Go

    Teamcenter Visualization and JT2Go are affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applicat…

  • High max 7.5

    Siemens SINEC Traffic Analyzer

    SINEC Traffic Analyzer before V2.0 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC Traffic Analyzer and recommends to update to the latest version.

  • Critical max 9.1
    ICSA-24-228-06 29 CVEs 1 exploited

    Siemens SINEC NMS

    SINEC NMS before V3.0 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC NMS and recommends to update to the latest version.

  • Medium max 6.7

    Siemens Location Intelligence

    Location Intelligence before V4.4 is affected by multiple vulnerabilities that could allow an attacker in an on-path position to read and modify data passed over the connection between legitimate clients and the affected product or brute force user passwords.…

  • High max 7.8

    Siemens COMOS

    COMOS before V10.5 is affected by two local code execution vulnerabilities in the integrated Open Design Alliance Drawings SDK. Siemens has released a new version for COMOS and recommends to update to the latest version.

  • High max 7.8

    Siemens NX

    NX (incl. NX student versions) before V2406.3000 contains an out-of-bounds read vulnerability that could be triggered when the application reads PRT files. If a user is tricked to open a malicious file using the affected application, this could lead to a cras…

  • High max 7.5

    Schneider Electric Accutech Manager

    Schneider Electric is aware of a vulnerability in its Accutech Manager software. The Accutech Manager software is the configuration and monitoring application for Accutech Wireless sensor devices. Failure to apply the remediations provided below may risk in r…

  • Medium max 5.3

    Dorsett Controls InfoScan

    Successful exploitation of these vulnerabilities could allow an attacker to expose sensitive information, resulting in data theft and misuse of credentials.

  • High max 7.8

    Delta Electronics DIAScreen

    Successful exploitation of this vulnerability could allow an attacker to cause a stack-based buffer overflow, resulting in execution of arbitrary code.

  • High max 9.0

    Johnson Controls exacqVision client and exacqVision server

    Successful exploitation of this vulnerability could allow an attacker to be able to decrypt communications between exacqVision Server and exacqVision Client due to insufficient key length and exchange.

  • Medium max 6.8

    Johnson Controls exacqVision Server web service

    Successful exploitation of this vulnerability could allow an attacker to send an unauthorized request or access data from an untrusted domain.

  • Medium max 6.8

    Johnson Controls exacqVision Web Service

    Successful exploitation of this vulnerability could allow an attacker to perform state-changing operations with administrative privileges.

  • Medium max 6.4

    Johnson Controls exacqVision Web Service

    Successful exploitation of this vulnerability could allow an attacker to perform a man-in-the-middle attack and gain access to sensitive information.

  • Medium max 6.4

    Johnson Controls exacqVision Server

    Successful exploitation of this vulnerability could allow an attacker to perform a man-in-the-middle attack and intercept communications.

  • Medium max 5.7

    Johnson Controls exacqVision Web Service

    Successful exploitation of this vulnerability may allow an attacker to gain sensitive information.

  • High max 8.8

    AVTECH IP camera

    Successful exploitation of this vulnerability could allow an attacker to inject and execute commands as the owner of the running process.

  • Critical max 10.0

    Vonets WiFi Bridges

    Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information, cause a denial-of-service condition, or execute arbitrary code on the affected device.

  • High max 7.3

    Rockwell Automation Logix Controllers

    Successful exploitation of this vulnerability could allow an attacker to execute CIP programming and configuration commands.

  • High max 8.7

    Positron Broadcast Signal Processor

    Successful exploitation of this vulnerability could allow an attacker to bypass authentication and access unauthorized protected areas of the application.

  • High max 7.1
    ICSA-22-333-02 1 CVE rev. 2

    Hitachi Energy IED Connectivity Packages and PCM600 Products (Update A)

    Successful exploitation of this vulnerability could allow an attacker to obtain sensitive credentials and gain access to the affected products, perform unauthorized modifications, or provoke a denial-of-service condition.

    first Nov 29, 2022
  • High max 7.8

    National Instruments IO Trace

    Successful exploitation of this vulnerability could allow a local attacker to execute arbitrary code.

  • High max 7.5

    Hitachi Energy AFS/AFR Series Products

    Successful exploitation of these vulnerabilities could allow an attacker to create a denial-of-service condition.

  • High max 7.8

    National Instruments LabVIEW

    Successful exploitation of these vulnerabilities could allow a local attacker to disclose information and execute arbitrary code.

  • Critical max 9.8

    Siemens SICAM Products

    Multiple SICAM products are affected by unauthorized password reset and firmware downgrade vulnerabilities that could lead to privilege escalation and potential leak of information, namely: - SICAM A8000 Device firmware - CPCI85 for CP-8031/CP-8050 - SICAM EG…

  • Medium max 6.5

    Subnet Solutions PowerSYSTEM Center

    Successful exploitation of this vulnerability could allow an authenticated attacker to elevate permissions.

  • High max 8.7

    Rockwell Automation Pavilion 8

    Successful exploitation of this vulnerability could allow an attacker to create new users and view sensitive data.

  • Critical max 9.3

    Rockwell Automation ThinManager ThinServer

    Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code or cause a denial-of-service condition.

  • Medium max 7.1

    Rockwell Automation FactoryTalk System Services and Policy Manager

    Successful exploitation of these vulnerabilities could allow an attacker to obtain private keys, which would result in impersonating resources on the secured network.

  • Medium max 6.3

    HMS Industrial Networks Anybus-CompactCom 30

    Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition, exfiltrate data, or obtain a high degree of control over the device and subsequent systems, including remote code execution .

  • Critical max 9.3
    ICSA-23-269-03 1 CVE rev. 2

    Mitsubishi Electric FA Engineering Software (Update A)

    Successful exploitation of this vulnerability could allow a local attacker to execute code, which could result in information disclosure, tampering with and deletion of information, or a denial-of-service (DoS) condition.

    first Sep 26, 2023
  • High max 8.8

    Mitsubishi Electric MELIPC Series MI5122-VW

    Successful exploitation of this vulnerability could allow an attacker to tamper with, destroy, disclose, or delete information in the product, or cause a denial-of-service (DoS) condition on the product.

  • Medium max 7.0

    Johnson Controls Illustra Pro Gen 4

    Successful exploitation of this vulnerability could impact confidentiality and integrity of the device.

  • High max 7.7

    Johnson Controls Inc. Software House C●CURE 9000

    Successful exploitations of this vulnerability could allow an attacker to gain administrative access

  • High max 7.5
    ICSA-17-339-01 1 CVE rev. 24

    Siemens Industrial Products (Update S)

    Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a denial of service attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released new versions for several affected products an…

    first Nov 23, 2017
  • High max 7.5
    ICSA-19-283-02 1 CVE rev. 18

    Siemens PROFINET Devices (Update K)

    A vulnerability in affected devices could allow an attacker to perform a denial of service attack if a large amount of specially crafted UDP packets are sent to the device. Siemens has released new versions for several affected products and recommends to upda…

    first Oct 8, 2019