Skip to content
OpenAdvisories

Source

CISA ICS & IT advisories

Source: https://www.cisa.gov/news-events/cybersecurity-advisories

4,108 results · Feed

  • High max 7.5

    Hitachi Energy Gateway Station

    Successful exploitation of these vulnerabilities could cause affected modules to stop working.

  • Medium max 4.6

    Rittal CMC III Access systems

    Successful exploitation of this vulnerability could allow an attacker to open control cabinets secured with Rittal locks.

  • Medium max 6.4

    Medtronic Micro Clinician and InterStim Apps

    Successful exploitation of this vulnerability could cause the clinician application’s custom password to be reset to default, resulting in unauthorized control of the clinician therapy application.

  • Critical max 8.1

    Baicells Nova

    Successful exploitation of this vulnerability could allow commands performed using pre-login execution and with root permissions.

  • Critical max 5.5

    Mitsubishi Electric MELSOFT iQ AppPortal

    Successful exploitation of these vulnerabilities could allow a malicious attacker to make unidentified impacts such as authentication bypass, information disclosure, denial-of-service, or bypass IP address authentication.

  • Critical max 9.8

    PTC ThingWorx Edge

    Successful exploitation of these vulnerabilities could allow an attacker to crash the device they accessed or could allow remote code execution.

    PTC
  • High max 7.3
    ICSMA-23-047-01 1 CVE rev. 2

    BD Alaris Infusion Central

    This updated advisory is a follow-up to the original advisory titled ICSMA-23-047-01 BD Alaris Infusion Central that was published February 16, 2023, to the ICS webpage on www.cisa.gov/uscert.

    first Feb 16, 2023
  • High max 7.6
    ICSA-22-333-04 1 CVE rev. 2

    Moxa UC Series

    This updated advisory is a follow-up to the original advisory titled ICSA-22-333-04 Moxa UC Series that was published November 29, 2022, on the ICS webpage on cisa.gov/ICS.

    first Nov 29, 2022
  • Medium max 5.3

    Sub-IoT DASH 7 Alliance Protocol stack implementation

    Successful exploitation of this vulnerability could allow an attacker to create an out-of-bounds write condition.

  • Critical max 9.3

    Weintek EasyBuilder Pro cMT Series

    Successful exploitation of this vulnerability could allow an attacker to gain control of the user's machine or gain sensitive information.

  • High max 8.8
    ICSA-22-298-06 14 CVEs rev. 2

    Delta Electronics DIAEnergie

    This updated advisory is a follow-up to the original advisory titled ICSA-22-298-06 Delta Electronics DIAEnergie (Update A) that was published November 10, 2022, to the ICS webpage at www.cisa.gov/uscert.

    first Nov 10, 2022
  • High max 7.5
    ICSA-22-286-07 1 CVE rev. 3

    Siemens Nucleus RTOS FTP Server

    The FTP server of the networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) does not properly release memory resources that were reserved for incomplete connection attempts by FTP clients. This could allow a remote attacker to genera…

    first Oct 11, 2022
  • Critical max 9.3
    ICSA-22-314-04 1 CVE rev. 2

    Siemens SINUMERIK ONE and SINUMERIK MC

    SINUMERIK ONE and SINUMERIK MC products are affected by a weak key protection vulnerability in the integrated S7-1500 CPU. The weak key protection vulnerability in the integrated S7-1500 CPU is documented in more detail in SSA-568427 [1]. Siemens has released…

    first Nov 8, 2022
  • Critical
    ICSA-22-314-10 13 CVEs rev. 2

    Siemens SCALANCE W1750D

    The SCALANCE W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or exploit buffer overflow vulnerabilities which could lead to denial of service, unauthenticated remote code execution or stored XSS. Siemens has rel…

    first Nov 8, 2022
  • High

    Siemens SCALANCE X200 IRT

    Products of the SCALANCE X-200IRT switch family are affected by a denial of service vulnerability in the SNMP agent that could allow remote attackers to cause a denial of service condition. Siemens has released updates for the affected products and recommends…

  • Critical max 9.8

    Siemens Brownfield Connectivity Client

    Siemens has released a new version for Brownfield Connectivity - Client that contains fixes for multiple vulnerabilities in the underlying OpenSSL library. Successful exploitation of these vulnerabilities could lead to Denial of Service (DoS). Siemens has rel…

  • High max 7.5

    Siemens Brownfield Connectivity Gateway

    Siemens has released a new version for Brownfield Connectivity - Gateway that contains fixes for multiple vulnerabilities in the underlying Golang implementation. Successful exploitation of these vulnerabilities could lead to Denial of Service (DoS). Siemens …

  • High max 7.8

    Siemens SiPass integrated AC5102 / ACC-G2 and ACC-AP

    SiPass integrated ACC (Advanced Central Controller) devices improperly sanitize user input on the telnet command line interface. This could allow an authenticated user to escalate privileges by injecting arbitrary commands that are executed with root privileg…

  • High max 7.8

    Siemens Simcenter Femap before V2023.1

    Simcenter Femap is affected by out of bounds read/write vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulner…

  • Critical max 10.0

    Siemens COMOS

    COMOS is affected by memory corruption vulnerability in the cache validation service that could allow an attacker to execute arbitrary code or cause denial of service condition. Siemens has released updates for the affected products and recommends to update t…

  • Medium max 5.9

    Siemens Mendix

    Mendix applications contain an improper access control vulnerability that could allow an attacker to bypass XPath constraints and retrieve information using XPath queries that trigger errors. Siemens has released updates for the affected products and recommen…

  • High max 7.8

    Siemens JT Open, JT Utilities, and Parasolid

    JT Open Toolkit, JT Utilities and Parasolid are affected by memory corruption vulnerabilities that could be triggered while parsing JT files. If a user is tricked to open a malicious JT file with any of the affected products, this could cause the application …

  • Medium max 5.5
    ICSA-22-354-03 2 CVEs rev. 2

    ARC Informatique PcVue

    Successful exploitation of these vulnerabilities could allow an unauthorized user to access the email account, SIM card, and other data sources associated with the affected device.

    first Dec 20, 2022
  • Critical max 9.1

    Control By Web X-400, X-600M

    Successful exploitation of these vulnerabilities could allow an attacker to inject malicious JavaScript and execute arbitrary code remotely, which could result in a loss of sensitive information.

  • Critical max 9.8

    LS ELECTRIC XBC-DN32U

    Successful exploitation of these vulnerabilities could allow an attacker to steal Programmable Logic Controller (PLC) information, cause users to lose communication with the PLC, modify PLC code, obtain credentials, and create a denial-of-service condition.

  • High max 7.5

    Johnson Controls System Configuration Tool (SCT)

    Successful exploitation of these vulnerabilities could allow an attacker to access cookies and take over the user's session.

  • High max 7.8

    Horner Automation Cscape Envision RV

    Successful exploitation of these vulnerabilities could lead to an attacker executing arbitrary code via malicious project files.

  • Medium max 6.3

    EnOcean SmartServer

    Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to the servers.

  • Critical max 8.1

    Baicells Nova

    Successful exploitation of this vulnerability could allow an attacker to execute arbitrary commands.

  • Critical max 9.8
    ICSA-22-221-01 2 CVEs rev. 4

    Mitsubishi Electric Multiple Factory Automation Products (Update B)

    Successful exploitation of these vulnerabilities could create a denial-of-service condition or enable arbitrary code execution.

    first Aug 30, 2022
  • High max 7.8

    Delta Electronics DIAScreen

    Successful exploitation of these vulnerabilities could allow remote code execution.

  • High max 6.8

    Mitsubishi Electric GOT2000 Series and GT SoftGOT2000

    Successful exploitation of these vulnerabilities could allow attackers to perform unintended operations through clickjacking (an attack that tricks users into clicking an invisible or disguised webpage element) or allow attackers to disclose sensitive informa…

  • Critical max 8.8

    Delta Electronics DVW-W02W2-E2

    Successful exploitation of this vulnerability could allow a threat actor with low privileges to gain root access to the device, which could then allow them to send malicious commands to managed devices.

  • Critical max 9.0

    Delta Electronics DX-2100-L1-CN

    Successful exploitation of these vulnerabilities could allow an attacker with low privileges to gain root access or allow an unauthenticated attacker to perform remote code execution.

  • High max 7.8

    Delta Electronics DOPSoft

    Successful exploitation of these vulnerabilities could allow for remote code execution.

  • Medium max 5.9
    ICSA-23-017-02 1 CVE rev. 2

    Mitsubishi Electric MELSEC iQ-F, iQ-R Series

    These products are available in limited regions.

    first Jan 17, 2023
  • High max 7.8

    Delta Electronics CNCSoft ScreenEditor

    Successful exploitation of this vulnerability could cause a buffer overflow condition, which could allow remote code execution.

  • High max 7.5

    Snap One Wattbox WB-300-IP-3

    Successful exploitation of these vulnerabilities could lead to remote code execution on the device, password brute force, and bricking of the device.

  • High max 8.8

    Sierra Wireless AirLink Router with ALEOS Software

    Successful exploitation of these vulnerabilities could allow a loss of sensitive information and could allow remote code execution.

  • High max 7.5

    Mitsubishi Electric MELFA SD/SQ series and F-series Robot Controllers