Skip to content
OpenAdvisories

Source

CISA ICS & IT advisories

Source: https://www.cisa.gov/news-events/cybersecurity-advisories

4,108 results · Feed

  • Critical

    AVEVA Wonderware License Server

    Successful exploitation of this vulnerability may result in remote code execution with administrative privileges.

  • Medium
    ICSA-17-313-01 1 CVE rev. 3

    AutomationDirect CLICK, C-More, C-More Micro, Do-more Designer, GS Drives, SL-Soft SOLO, DirectSOFT (Update B)

    Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code on the system.

    first Nov 9, 2017
  • Critical

    AVEVA InduSoft Web Studio and InTouch Machine Edition

    The listed products are vulnerable only if the TCP/IP Server Task is enabled. A remote attacker could send a carefully crafted packet during a tag, alarm, or event related action such as read and write, which may allow remote code execution.

  • Critical

    AVEVA InTouch

    Successful exploitation of this vulnerability could allow an unauthenticated user to remotely execute code with the same privileges as those of the InTouch View process which could lead to a compromise of the InTouch HMI.Systems are only vulnerable if the ope…

  • High

    Moxa NPort 5210 5230 5232

    Successful exploitation of this vulnerability could allow a remote attacker to send TCP SYN packages, causing a resource exhaustion condition that would cause the device to become unavailable.

  • High
    ICSA-18-172-02 1 CVE rev. 2

    Rockwell Automation Allen-Bradley CompactLogix and Compact GuardLogix (Update A)

    Successful exploitation of this vulnerability could result in a denial-of-service condition. As a result, the controller goes into a Major Non-Recoverable Fault (MNRF) state, which is considered safe. However, recovery requires the user to download the applic…

    first Jun 21, 2018
  • High

    ABB Panel Builder 800

    An attacker could exploit the vulnerability by tricking a user to open a specially crafted file, allowing the attacker to insert and run arbitrary code. This vulnerability requires user interaction, and the exploit is only triggered when a local user runs the…

    ABB
  • High

    WAGO e!DISPLAY Web-Based-Management

    Successful exploitation of these vulnerabilities could allow an attacker to execute code in the context of the user, execute code within the user 's browser, place malicious files within the filesystem, and replace existing files to allow privilege escalation.

  • High

    PEPPERL+FUCHS VisuNet RM, VisuNet PC, and Box Thin Client

    Successful exploitation of this vulnerability could allow attackers to intercept sensitive communications, establish a man-in-the-middle attack, achieve administrator privileges, and execute remote code.

  • Medium max 6.3
    ICSMA-18-137-01 2 CVEs rev. 2

    Medtronic N'Vision Clinician Programmer (Update A)

    As part of the normal functionality of this device, the N 'Vision Clinician Programmer may store Personal Health Information (PHI) or Personal Identifying Information (PII). Successful exploitation of these vulnerabilities may allow an attacker with physical …

    first May 17, 2018
  • Medium

    Eaton 9000X Drive

    Successful exploitation of this vulnerability may allow remote code execution.

  • Critical

    Universal Robots Robot Controllers

    Successful exploitation of these vulnerabilities could allow a remote attacker to run arbitrary code on the device.

  • High

    Schweitzer Engineering Laboratories, Inc. Compass and AcSELerator Architect

    Successful exploitation of these vulnerabilities could allow modification/replacement of files within the Compass installation directory, disclosure of information, or denial of service.

  • High max 7.5
    ICSA-18-184-01 5 CVEs 1 exploited

    Rockwell Automation Allen-Bradley Stratix 5950

    Successful exploitation of these vulnerabilities could allow an attacker to bypass client certification to create connections to the affected device or cause the device to crash.

  • Medium max 6.4

    Medtronic MyCareLink Patient Monitor

    If exploited, these vulnerabilities may allow privileged access to the monitor 's operating system. However, physical access to the MyCareLink monitor is required. Additionally, these vulnerabilities may allow a MyCareLink monitor, when operated within close …

  • High

    Delta Electronics Delta Industrial Automation COMMGR

    Successful exploitation of this vulnerability may allow remote code execution, cause the application to crash, or cause a denial-of-service condition in the application server.

  • Critical max 10.0

    Natus Xltek NeuroWorks

    Successful exploitation of these vulnerabilities require access to the Natus customer network, and could crash the device being accessed; a buffer overflow condition may allow remote code execution.

  • Critical
    ICSA-17-045-03 1 CVE rev. 5

    ICSA-17-045-03 Siemens SIMATIC Authentication Bypass (Update D)

    first Feb 13, 2017
  • High
    ICSA-17-187-03F 6 CVEs rev. 9

    ICSA-17-187-03F Siemens SIPROTEC 4 and SIPROTEC Compact (Update F)

    first Jul 4, 2017
  • Medium
    ICSA-17-306-01 1 CVE rev. 2

    ICSA-17-306-01 Siemens SIMATIC PCS 7 (Update A)

    first Oct 18, 2017
  • Critical

    Schneider Electric U.motion Builder

    Successful exploitation of these vulnerabilities could allow remote code execution.

  • High
    ICSA-18-137-04 1 CVE rev. 2

    Delta Electronics Delta Industrial Automation TPEditor (Update A)

    Successful exploitation of this vulnerability could crash the accessed device, resulting in a buffer overflow condition that may allow remote code execution.

    first May 17, 2018
  • High

    Rockwell Automation RSLinx Classic and FactoryTalk Linx Gateway

    Successful exploitation of this vulnerability could allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation.

  • High
    ICSMA-18-128-01 2 CVEs rev. 3

    Silex Technology SX-500/SD-320AN or GE Healthcare MobileLink (Update B)

    Successful exploitation of these vulnerabilities could allow modification of system settings and remote code execution.

    first May 8, 2018
  • Critical

    ABB IP Gateway

    Successful exploitation of these vulnerabilities could allow attackers to perform actions using administrative privileges.

    ABB
  • High
    ICSMA-18-156-01 3 CVEs rev. 2

    Philips' IntelliVue Patient and Avalon Fetal Monitors

    Successful exploitation may allow an attacker to read/write memory, and/or induce a denial of service through a system restart, thus potentially leading to a delay in diagnosis and treatment of patients.

  • Critical
    ICSA-18-102-02 2 CVEs rev. 4

    Rockwell Automation FactoryTalk Activation Manager (Update B)

    Successful exploitation of these vulnerabilities could allow a remote attacker to access sensitive information, rewrite content, or cause a buffer overflow that could result in remote code execution.

    first Apr 12, 2018
  • High

    ICSA-18-151-01_Delta Industrial Automation DOPSoft

    B0nd @garagehackers working with Trend Micro 's Zero Day Initiative reported the vulnerabilities to NCCIC.

  • High

    GE MDS PulseNET and MDS PulseNET Enterprise

    Exploitation of these vulnerabilities may allow elevation of privilege and exfiltration of information on the host platform.

  • Critical

    Schneider Electric Floating License Manager

    Successful exploitation of these vulnerabilities could cause a denial of service, allow arbitrary execution of code with system level privileges, or send users to arbitrary websites.

  • High

    BeaconMedaes TotalAlert Scroll Medical Air Systems

    Successful exploitation of these vulnerabilities could allow an attacker to view and potentially modify some device information and web application setup information, which does not include access to patient health information. Additionally, BeaconMedaes has …

  • High
    ICSA-18-128-02 1 CVE rev. 2

    ICSA-18-128-02 Siemens Siveillance VMS (Update A)

    first May 3, 2018
  • Medium max 5.9

    Philips EncoreAnywhere

    Successful exploitation of this vulnerability could result in unencrypted communication and potential improper disclosure of sensitive data.

  • High

    GE PACSystems CPE305/310, CPE330, CPE400, RSTi-EP CPE 100, CPU320/CRU320, RXi

    Successful exploitation of this vulnerability could cause the device to reboot and change its state, causing the device to become unavailable.

  • Critical

    PHOENIX CONTACT FL SWITCH 3xxx/4xxx/48xx Series

    Successful exploitation of these vulnerabilities could allow for remote code execution and information disclosure.

  • Critical
    ICSA-18-135-01 11 CVEs

    Advantech WebAccess

    Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information from the host and/or target, execute arbitrary code, or delete files.

  • Medium

    MatrikonOPC Explorer

    If the attacker has local access to the system, an attacker could exploit this vulnerability. This could allow an attacker to transfer unauthorized files from the host system, which could result in unauthorized information disclosure.

  • Medium

    Rockwell Automation Arena

    Successful exploitation of this vulnerability could cause the software application to crash.

  • High
    ICSA-17-332-01 4 CVEs rev. 3

    Siemens SCALANCE W1750D, M800, S615, and RUGGEDCOM RM1224 (Update C)

    first Nov 17, 2017
  • Critical
    ICSA-18-025-01 1 CVE rev. 2

    Nari PCS-9611 (Update A)

    Successful exploitation of this vulnerability could allow a remote attacker arbitrary read/write abilities on the system.

    first Jan 25, 2018