Weakness (CWE)
CWE-1263: Improper Physical Access Control
The product is designed with access restricted to certain information, but it does not sufficiently protect against an unauthorized actor with physical access to these areas.
More detail
The specific requirements around how robust the design of the physical protection mechanism depends on the type of product being protected. Selecting the correct physical protection mechanism and properly enforcing it through implementation and manufacturing are critical to the overall physical security of the product.
How to prevent it (3 mitigations)
-
Architecture and Design
Specific protection requirements depend strongly on contextual factors including the level of acceptable risk associated with compromise to the product's protection mechanism. Designers could incorporate anti-tampering measures that protect against or detect when the product has been tampered with.
-
Testing
The testing phase of the lifecycle should establish a method for determining whether the protection mechanism is sufficient to prevent unauthorized access.
-
Manufacturing
Ensure that all protection mechanisms are fully activated at the time of manufacturing and distribution.
Source: MITRE CWE-1263
10 results · Clear filters · Feed
-
Medium 6.8
An improper physical access control issue exists in ShizenBox2 (dev-conf). If exploited, an attacker with physical acce…
-
Medium 6.8
Medtronic MyCareLink Patient Monitor Hardware Debug Port
Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART terminal.
-
Medium 4.7
Tesla Model 3 Physical CAN Bus Injection
Securing externally available CAN wires can easily allow physical access to the CAN bus, allowing possible injection of specially formed CAN messages to control remote start functions of the vehicle. Testing completed on Tesla Model 3 vehicles with software …
-
Medium 6.8
INSTAR 2K+/4K UART improper physical access control
A vulnerability was found in INSTAR 2K+ and 4K 3.11.1 Build 1124. This issue affects some unknown processing of the component UART Interface. The manipulation leads to improper physical access control. It is possible to launch the attack on the physical devic…
-
Medium 6.6
Junos OS Evolved: User is not logged out when the console cable is disconnected
An Improper Physical Access Control vulnerability in the console port control of Juniper Networks Junos OS Evolved allows an attacker with physical access to the device to get access to a user account. When the console cable is disconnected, the logged in use…
-
Medium 6.4
An issue was discovered on certain Nuki Home Solutions devices. An attacker with physical access to the circuit board c…
-
Medium 6.8
Incorrect Access Control in ASUS RT-N12+ B1 and RT-N12 D1 routers allows local attackers to obtain root terminal access…
-
Medium 6.1
A vulnerability was reported in ThinkPad T14s Gen 3 and X13 Gen3 that could cause the BIOS tamper detection mechanism t…
-
Medium 6.1
A vulnerability was reported in ThinkPad T14s Gen 3 and X13 Gen3 that could cause the BIOS tamper detection mechanism t…
-
Medium 6.1
A vulnerability was reported in ThinkPad T14s Gen 3 and X13 Gen3 that could cause the BIOS tamper detection mechanism t…