Medium 5.5
AutomationDirect Productivity Suite Divide By Zero
A divide-by-zero vulnerability in the Productivity Suite allows a local attacker to cause a division by zero leading to a system crash.
-
Medium 5.9
AutomationDirect Productivity Suite Out-of-bounds Read
An out-of-bounds read in the Productivity Suite allows a physical attacker to control the length of data sent to a USB device. This can lead to a system crash or disclosure of kernel memory.
-
Medium 6.1
AutomationDirect Productivity Suite Out-of-bounds Read
An out-of-bounds read vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption by sending a crafted IOCTL request. This could lead to limited information disclosure or disruption of the affected product.
-
Medium 6.1
AutomationDirect Productivity Suite Out-of-bounds Read
An out-of-bounds read vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption by sending a crafted IOCTL request. This can lead to exposing sensitive information or causing the affected product to become unstable or…
-
Medium 6.1
AutomationDirect CLICK Programmable Logic Controller Plaintext Storage of a Password
An attacker could decrypt sensitive data, impersonate legitimate users or devices, and potentially gain access to network resources for lateral attacks.
-
Medium 6.1
AutomationDirect CLICK Programmable Logic Controller Weak Encoding for Password
An attacker with access to the project file could use the exposed credentials to impersonate users, escalate privileges, or gain unauthorized access to systems and services. The absence of robust encryption or secure handling mechanisms increases the likeliho…
-
Medium 4.0
AutomationDirect Productivity Suite Relative Path Traversal
A relative path traversal vulnerability was discovered in Productivity Suite software version 4.4.1.19. The vulnerability allows an unauthenticated remote attacker to interact with the ProductivityService PLC simulator and delete arbitrary directories on the …
-
Medium 4.0
AutomationDirect Productivity Suite Relative Path Traversal
A relative path traversal vulnerability was discovered in Productivity Suite software version 4.4.1.19. The vulnerability allows an unauthenticated remote attacker to interact with the ProductivityService PLC simulator and create arbitrary directories on the …
-
Medium 6.8
AutomationDirect Productivity Suite Relative Path Traversal
A relative path traversal vulnerability was discovered in Productivity Suite software version 4.4.1.19. The vulnerability allows an unauthenticated remote attacker to interact with the ProductivityService PLC simulator and read arbitrary files on the target m…
-
Medium 5.9
AutomationDirect CLICK PLUS Improper Resource Shutdown or Release
An improper resource shutdown or release vulnerability has been identified in the Click Plus C2-03CPU-2 device running firmware version 3.60. The vulnerability allows an unauthenticated attacker to perform a denial-of-service attack by exhausting all availabl…
-
Medium 6.8
AutomationDirect CLICK PLUS Missing Authorization
An authorization bypass vulnerability has been discovered in the Click Plus C2-03CPU2 device firmware version 3.60. Through the KOPR protocol utilized by the Remote PLC application, authenticated users with low-level access permissions can exploit this vulner…
-
Medium 5.9
AutomationDirect CLICK PLUS Improper Resource Shutdown or Release
An improper resource shutdown or release vulnerability has been identified in the Click Plus C2-03CPU-2 device running firmware version 3.60. The vulnerability allows an unauthenticated attacker to perform a denial-of-service attack by exhausting all availabl…
-
Medium 5.3
AutomationDirect CLICK PLUS Use of Hard-coded Cryptographic Key
The use of a hard-coded cryptographic key was discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software contains a hard-coded AES key used to protect the initial messages of a new KOPS session.
-
Medium 4.2
AutomationDirect CLICK PLUS Cleartext Storage of Sensitive Information
Cleartext storage of sensitive information was discovered in Click Programming Software version v3.60. The vulnerability can be exploited by a local user with access to the file system, while an administrator session is active, to steal credentials stored in …
-
Medium 6.5
AutomationDirect C-MORE EA9 HMI Plaintext Storage of a Password
In AutomationDirect C-MORE EA9 HMI, credentials used by the platform are stored as plain text on the device.
-
Medium 4.3
AutomationDirect C-MORE EA9 HMI Stack-based Buffer Overflow
In AutomationDirect C-MORE EA9 HMI there is a program that copies a buffer of a size controlled by the user into a limited sized buffer on the stack which may lead to a stack overflow. The result of this stack-based buffer overflow can lead to denial-of-servi…