Vendor
Bosch
73 known vulnerabilities.
Products
73 results · Feed
-
High 8.8
B426 Credential Disclosure
When using http protocol, the user password is transmitted as a clear text parameter for which it is possible to be obtained by an attacker through a MITM attack. This will be fixed starting from Firmware version 3.11.5, which will be released on the 30th of …
-
High 8.0
B426 Web Configuration Authentication Bypass
This vulnerability could allow an attacker to hijack a session while a user is logged in the configuration web page. This vulnerability was discovered by a security researcher in B426 and found during internal product tests in B426-CN/B429-CN, and B426-M and …
-
High 8.3
Reflected XSS in page parameter
An error in the handling of a page parameter in Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. This issue only affects versions 7.7x and 7.6x. All other versions are not affected.
-
Critical 9.8
Unauthenticated Information Extraction Vulnerability
A Missing Authentication in Critical Function in Bosch IP cameras allows an unauthenticated remote attacker to extract sensitive information or change settings of the camera by sending crafted requests to the device. Only devices of the CPP6, CPP7 and CPP7.3 …
-
High 8.3
Improper Input Validation of HTTP Headers
In Bosch IP cameras, improper validation of the HTTP header allows an attacker to inject arbitrary HTTP headers through crafted URLs.
-
High 8.3
Reflected XSS in URL handler
An error in the URL handler Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. An attacker with knowledge of the camera address can send a crafted link to a user, which will execute javascript code in the context o…
-
Medium 4.9
Denial of Service (DoS) due to invalid web parameter
An authenticated attacker with administrator rights Bosch IP cameras can call an URL with an invalid parameter that causes the camera to become unresponsive for a few seconds and cause a Denial of Service (DoS).
-
High 7.8
Uncontrolled Search Path Element in Bosch Video Streaming Gateway Installer
Calling an executable through an Uncontrolled Search Path Element in the Bosch Video Streaming Gateway installer up to and including version 6.45.10 potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the vict…
-
High 7.8
Uncontrolled Search Path Element in Bosch Monitor Wall Installer
Loading a DLL through an Uncontrolled Search Path Element in the Bosch Monitor Wall installer up to and including version 10.00.0164 potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the victim is tricked in…
-
High 7.8
Uncontrolled Search Path Element in Bosch Configuration Manager Installer
Loading a DLL through an Uncontrolled Search Path Element in the Bosch Configuration Manager installer up to and including version 7.21.0078 potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the victim is tr…
-
High 7.8
Uncontrolled Search Path Element in Bosch Video Client installer
Loading a DLL through an Uncontrolled Search Path Element in the Bosch Video Client installer up to and including version 1.7.6.079 potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the victim is tricked int…
-
High 7.8
Uncontrolled Search Path Element in Bosch Video Recording Manager Installer
Loading a DLL through an Uncontrolled Search Path Element in the Bosch Video Recording Manager installer up to and including version 3.82.0055 for 3.82, up to and including version 3.81.0064 for 3.81 and 3.71 and older potentially allows an attacker to execut…
-
High 7.8
Uncontrolled Search Path Element in Bosch BVMS and BVMS Viewer
Loading a DLL through an Uncontrolled Search Path Element in Bosch BVMS and BVMS Viewer in versions 10.1.0, 10.0.1, 10.0.0 and 9.0.0 and older potentially allows an attacker to execute arbitrary code on a victim's system. This affects both the installer as we…
-
High 7.8
Uncontrolled Search Path Element in Bosch IP Helper
Loading a DLL through an Uncontrolled Search Path Element in Bosch IP Helper up to and including version 1.00.0008 potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the victim is tricked into placing a malic…
-
Medium 4.4
Password Hash With Insufficient Computational Effort in the Database of Bosch FSM-2500 Server and Bosch FSM-5000 Server
Use of Password Hash With Insufficient Computational Effort in the database of Bosch FSM-2500 server and Bosch FSM-5000 server up to and including version 5.2 allows a remote attacker with admin privileges to dump the credentials of other users and possibly r…
-
Critical 10.0
Hard-coded Credentials in the Database of Bosch FSM-2500 Server and Bosch FSM-5000 Server
Use of Hard-coded Credentials in the database of Bosch FSM-2500 server and Bosch FSM-5000 server up to and including version 5.2 allows an unauthenticated remote attacker to log into the database with admin-privileges. This may result in complete compromise o…
-
Medium 4.8
Stored XSS in Bosch PRAESIDEO and Bosch PRAESENSA Management Interface
A vulnerability in the web-based management interface of Bosch PRAESIDEO until and including version 4.41 and Bosch PRAESENSA until and including version 1.10 allows an authenticated remote attacker with admin privileges to mount a stored Cross-Site-Scripting…
-
High 8.8
CSRF in Bosch PRAESIDEO and Bosch PRAESENSA Management Interface
A vulnerability in the web-based management interface of Bosch PRAESIDEO until and including version 4.41 and Bosch PRAESENSA until and including version 1.10 allows an unauthenticated remote attacker to trigger actions on an affected system on behalf of anot…
-
Medium 6.8
Improper Certificate Validation in Bosch Smart Home System App for iOS
Improper certificate validation for certain connections in the Bosch Smart Home System App for iOS prior to version 9.17.1 potentially allows to intercept video contents by performing a man-in-the-middle attack.
-
Critical 9.3
Kiosk Mode Breakout in Bosch Recording Station
Improper Access Control in the Kiosk Mode functionality of Bosch Recording Station allows a local unauthenticated attacker to escape from the Kiosk Mode and access the underlying operating system.
-
Critical 10.0
Deserialization of Untrusted Data in Bosch BVMS Mobile Video Service
Deserialization of Untrusted Data in the BVMS Mobile Video Service (BVMS MVS) allows an unauthenticated remote attacker to execute arbitrary code on the system. This affects Bosch BVMS versions 10.0 <= 10.0.0.1225, 9.0 <= 9.0.0.827, 8.0 <= 8.0.0.329 and 7.5 a…
-
High 8.6
Path Traversal in Bosch Video Management System (BVMS)
A path traversal vulnerability in the Bosch Video Management System (BVMS) NoTouch deployment allows an unauthenticated remote attacker to read arbitrary files from the Central Server. This affects Bosch BVMS versions 10.0 <= 10.0.0.1225, 9.0 <= 9.0.0.827, 8.…
-
Critical 10.0
Missing Authentication for Critical Function in Bosch Video Streaming Gateway
Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiali…
-
High 7.7
Path Traversal in Bosch Video Management System (BVMS)
A path traversal vulnerability in the Bosch Video Management System (BVMS) FileTransferService allows an authenticated remote attacker to read arbitrary files from the Central Server. This affects Bosch BVMS versions 10.0 <= 10.0.0.1225, 9.0 <= 9.0.0.827, 8.0…
-
High 8.8
An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a c…
-
Critical 9.9
Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The ser…
-
High 8.6
Server-side request forgery in the backup & restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software
A Server-Side Request Forgery (SSRF) vulnerability in the backup & restore functionality in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.3.0 allows a remote attacker to forge GET requests to arbitrary URLs. In addition, this co…
-
Medium 5.5
Incorrect pviilege assignment in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC)
A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.907 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerabi…
-
Medium 5.3
Improper access control in the JSON-RPC interface of the Bosch Smart Home Controller (SHC)
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a successful denial of service of the SHC and connected sensors and actuators. In order to exploit th…
-
Medium 5.7
Improper access control in the backup mechanism of the Bosch Smart Home Controller (SHC)
A potential improper access control vulnerability exists in the backup mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in unauthorized download of a backup. In order to exploit the vulnerability, the adversary needs to downlo…
-
Medium 5.5
Incorrect privilege assignment in the app permission update API of the Bosch Smart Home Controller (SHC)
A potential incorrect privilege assignment vulnerability exists in the app permission update API of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerabili…
-
High 7.5
Improper access control in the JSON-RPC interface of the Bosch Smart Home Controller (SHC)
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in reading or modification of the SHC's configuration or triggering and restoring backups. In order to e…
-
High 8.0
Incorrect privilege assignment in the app pairing mechanism of the Bosch Smart Home Controller (SHC)
A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the…