Skip to content
OpenAdvisories

Product · Delta Electronics

Delta UFC500

4 known vulnerabilities.

3 results · Clear filters · Feed

  • High 8.7

    Missing authentication check on POST/PUT requests

    The web server does not check authentication on POST or PUT. An unauthenticated attacker can reboot the charger; by brute-forcing the configid, they can also set the service password and then change any setting.

  • High 8.7

    Use of default password based on serial number

    Delta UFC500 charging stations derive the default credentials of the Service account from character positions of the device serial number. An unauthenticated attacker with adjacent network access can reconstruct the resulting password, or exhaust the keyspace…

  • High 8.4

    Default WebUI passwords stored in plaintext

    The shipped WebUI template database retains the factory default passwords for all five account types in cleartext. Defaults are identical across devices and were unchanged on the tested unit.