Skip to content
OpenAdvisories

Vendor

Dräger

16 known vulnerabilities.

8 results · Clear filters · Feed

  • Medium 6.5

    Dräger SC Monitoring Devices DoS via Malformed Network Packet

    Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers c…

  • Medium 6.8

    Dräger Zeus IE Anesthesia Workstation USB Interface Privilege Escalation

    Dräger Zeus Infinity Empowered (Zeus IE) and Zeus RS C500 anesthesia workstations contain a local security vulnerability that allows unauthorized individuals with physical access to compromise software integrity via USB interface manipulation. Attackers can e…

  • Medium 4.0

    Dräger Atlan A350 1.00 <= 1.01 DoS via Medibus Interface

    Dräger Atlan A350 versions 1.00 up to and including 1.01 contains an improper input handling vulnerability that allows attackers to cause a denial of service by sending specifically crafted non-Medibus-compliant data through the Medibus interface. Attackers c…

  • Medium 6.5

    Dräger Infinity M300 VG2.x Network-Based Denial of Service

    Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the dev…

  • Medium 4.0

    Dräger Perseus A500 2.00-2.02 DoS via Medibus Interface

    Dräger Perseus A500 software versions 2.00 through 2.02 contains an improper input handling vulnerability that allows external attackers to cause a denial of service by sending specifically crafted non-Medibus-compliant data through the Medibus interface. Att…

  • Medium 6.5

    Dräger Infinity M300 VG2.3.1 Network-Based Denial of Service

    Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Inf…

  • Medium 4.3

    Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure

    Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location informat…

  • Medium 6.5

    Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet

    Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to…