2 results · Clear filters · Feed

  • High 7.4

    ePA 3.x Integration: AES-GCM Nonce Reuse via Frozen VAU Request Counter

    ePA 3.x Integration implements the authorization workflow and writes Medical Information Objects to Germany's electronic patient record. Prior to 1.3.0, ePA 3.x Integration leaves request_counter unchanged in app/vau/VAUProtokoll.py while constructing VAU mes…

  • High 7.5

    ePA 3.x Integration: TLS Certificate Verification Universally Disabled

    ePA 3.x Integration implements the authorization workflow and writes Medical Information Objects to Germany's electronic patient record. Prior to 1.3.0, ePA 3.x Integration disables TLS certificate verification for both ePA connections in app/vau/VAUProtokoll…