118 known vulnerabilities.

51 results · Clear filters · Feed

  • Medium 6.9

    A vulnerability exists in the Equipment Tag Out authentication, when configured with Single Sign-On (SSO) with password…

  • Medium 4.0

    A vulnerability exists in a FOXMAN-UN and UNEM logging component, it only affects systems that use remote authenticatio…

  • Medium 4.8

    SDM600 API permission check

    A vulnerability exists in a SDM600 endpoint. An attacker could exploit this vulnerability by running multiple parallel requests, the SDM600 web services become busy rendering the application unresponsive. This issue affects: All SDM600 versions prior to versi…

  • Medium 5.9

    IEC 61850 MMS-Server Vulnerability in multiple Hitachi Energy Products

    A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products.  An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to st…

  • Medium 5.7

    A vulnerability exists in the Lumada APM’s User Asset Group feature due to a flaw in access control mechanism implementation on the “Limited Engineer” role.

    A vulnerability exists in the affected versions of Lumada APM’s User Asset Group feature due to a flaw in access control mechanism implementation on the “Limited Engineer” role, granting it access to the embedded Power BI reports feature. An attacker that man…

  • Medium 5.3

    A vulnerability exists in the handling of a malformed IEC 104 TCP packet. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected conne ...

    Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connect…

  • Medium 5.0

    HTTP Response Splitting in Hitachi Energy’s MSM Product

    A vulnerability exists in the http web interface where the web interface does not validate data in an HTTP header. This causes a possible HTTP response splitting, which if exploited could lead an attacker to channel down harmful code into the user’s web brows…

  • Medium 5.0

    Cross Site Request Forgery (CSRF) in Hitachi Energy’s MSM Product

    A vulnerability exists in the HTTP web interface where the web interface does not sufficiently verify if a well-formed, valid, consistent request was intentionally provided by the user who submitted the request. This cause a Cross Site Request Forgery (CSRF),…

  • Medium 6.0

    User authentication bypass in TXpert Hub CoreTec 4

    A vulnerability in the application authentication and authorization mechanism in Hitachi Energy's TXpert Hub CoreTec 4, that depends on a token validation of the session identifier, allows an unauthorized modified message to be executed in the server enabling…

  • Medium 4.2

    OWASP Related Vulnerabilities in Hitachi Energy’s LinkOne Product

    Cross-site Scripting (XSS) vulnerability in Hitachi Energy LinkOne allows an attacker that manages to exploit the vulnerability can take advantage to exploit multiple web attacks and stole sensitive information. This issue affects: Hitachi Energy LinkOne 3.20…

  • Medium 6.7

    Certificate verification vulnerability in Update Manager of PCM600 Engineering Tool

    A certificate validation vulnerability in PCM600 Update Manager allows attacker to get unwanted software packages to be installed on computer which has PCM600 installed.