12 results · Clear filters · Feed
-
High 8.2
Power System Integer Overflow
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 through OP940.81 (Power HMC) is affected by a vulnerability in the interface between th…
-
High 7.3
Power System Out-of-bounds Read
IBM Power Systems Firmware FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 - OP940.81 (Power HMC) is affected by a vulnerability in host firmware NVRAM parsing. An attacker with root access to a guest partition on an OpenPOWER syst…
-
High 7.9
Power System Incorrect Authorization
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can acce…
-
High 8.4
Power System Buffer Overflow
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the FSP management network protocol. An attacker with authenticated HMC administrator access can ex…
-
High 8.3
Power System Cross-Site Request Forgery (CSRF)
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An attacker who can lure a logged-in ASMI administrator to visit a crafted …
-
High 7.6
Power System Out-of-bounds Read
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI we…
-
High 8.2
Power System Buffer Overflow
IBM Power Systems Firmware FW1120.00, and FW1110.00 through FW1110.30 is affected by a vulnerability in the interface between the BMC and the host system. An attacker with service access to the BMC can send a specially crafted command, allowing arbitrary code…
-
High 8.1
Power System Incorrect Authorization
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 - OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/…
-
High 8.2
Power System Missing Authorization
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can exec…
-
High 8.2
Power System Buffer Overflow
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 - OP940.81 (Power HMC) is affected by a vulnerability in host firmware configuration pa…
-
High 8.2
Power System Out-of-bounds Write
Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1, and OP940.00 - OP940.81 is affected by a vulnerability in the service processor mailbox interface. An attacker wi…
-
High 8.2
Power System Buffer Overflow
Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the host firmware boot process image validation path. An attacker with service access to the service processor can supply a malici…