Vendor
Siemens
1,854 known vulnerabilities.
Products
JT2Go 153
Teamcenter Visualization 93
Tecnomatix Plant Simulation V2302 75
TeleControl Server Basic 73
Teamcenter Visualization V14.3 65
Teamcenter Visualization V14.2 63
SINEC NMS 56
Teamcenter Visualization V14.1 50
Solid Edge SE2023 49
Teamcenter Visualization V2312 48
Simcenter Femap 47
Teamcenter Visualization V13.3 47
SINEMA Remote Connect Server 47
Parasolid V35.0 44
Parasolid V34.1 41
Tecnomatix Plant Simulation V2404 40
Teamcenter Visualization V14.0 39
Tecnomatix Plant Simulation V2201 36
SPPA-T3000 MS3000 Migration Server 35
RUGGEDCOM ROX MX5000 34
RUGGEDCOM ROX RX1400 34
RUGGEDCOM ROX RX1500 34
RUGGEDCOM ROX RX1501 34
RUGGEDCOM ROX RX1510 34
RUGGEDCOM ROX RX1511 34
RUGGEDCOM ROX RX1512 34
RUGGEDCOM ROX RX1524 34
RUGGEDCOM ROX RX1536 34
RUGGEDCOM ROX RX5000 34
Solid Edge SE2021 33
Tecnomatix Plant Simulation 33
JT Utilities 32
Parasolid V34.0 31
SCALANCE M804PB 31
SCALANCE M826-2 SHDSL-Router 31
SCALANCE M874-2 31
SCALANCE M874-3 31
SCALANCE M876-3 (ROK) 31
SCALANCE M876-4 (EU) 31
SCALANCE M876-4 (NAM) 31
114 results · Clear filters · Feed
-
Critical 9.6
Affected devices do not properly validate and sanitize visual marker data contained in imported CSV trace files before …
-
Critical 9.6
Affected devices do not properly sanitize comment fields contained in imported trace files before rendering them on the…
-
Critical 9.6
Affected devices do not properly restrict executable content contained in imported trace files. This could allow an att…
-
Critical 9.1
Affected systems do not properly restrict access to internal APIs and paths for authenticated users. This could allow a…
-
Critical 9.8
A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). Information is exposed through the web int…
-
Critical 9.0
A vulnerability has been identified in Siveillance Control Pro V3.0 (All versions < V3.0.12.2173), Siveillance Control …
-
Critical 10.0CVE-2026-58115 Public exploit
A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running I…
-
Critical 10.0
A vulnerability has been identified in Opcenter X (All versions < V2604). Affected applications do not properly validat…
-
Critical 9.1CVE-2026-41551 Public exploit
A vulnerability has been identified in ROS# (All versions < V2.2.2). Affected versions contain a path traversal vulnera…
-
Critical 9.1
Affected devices do not properly validate and sanitize Technology Object (TO) name rendered on the "Motion Control Diag…
-
Critical 9.1
Affected devices do not properly validate and sanitize PLC/station name rendered on the "communication" parameters page…
-
Critical 9.1
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V5.0). The affected application does not properl…
-
Critical 9.1
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.1), RUGGEDCOM ROX MX5000RE (All versi…
-
Critical 9.6
Affected devices do not properly sanitize contents of trace files. This could allow an attacker to inject code through …
-
Critical 10.0
Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauth…
-
Critical 9.8
A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 15…
-
Critical 9.8
A vulnerability has been identified in TeleControl Server Basic V3.1 (All versions >= V3.1.2.2 < V3.1.2.3). The affecte…
-
Critical 9.1
A vulnerability has been identified in SIMATIC Virtualization as a Service (SIVaaS) (All versions). The affected applic…
-
Critical 9.8
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATI…
-
Critical 9.1
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V3.2). Affected products do not pr…
-
Critical 9.8
A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application exposes an endpoint th…
-
Critical 9.9
A vulnerability has been identified in Energy Services (All versions with G5DFR). Affected solutions using G5DFR contai…
-
Critical 9.9
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versi…
-
Critical 9.9
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versi…
-
Critical 9.9
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versi…
-
Critical 9.8
A vulnerability has been identified in OZW672 (All versions < V6.0), OZW772 (All versions < V6.0). The web service of a…
-
Critical 10.0
A vulnerability has been identified in OZW672 (All versions < V8.0), OZW772 (All versions < V8.0). The web service in a…
-
Critical 9.8
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is …
-
Critical 9.8
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is …
-
Critical 9.8
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is …
-
Critical 9.8
A vulnerability has been identified in Industrial Edge Device Kit - arm64 V1.17 (All versions), Industrial Edge Device …
-
Critical 10.0
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Affected devices contain hardco…
-
Critical 9.1
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected d…
-
Critical 9.1
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected d…
-
Critical 9.1
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected d…
-
Critical 9.1
A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.9), SiPass integrated ACC…
-
Critical 9.8
A vulnerability has been identified in SINAMICS S200 (All versions with serial number beginning with SZVS8, SZVS9, SZVS…
-
Critical 9.8
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2501.0001), Opcenter Intelligence…
-
Critical 9.8
A vulnerability has been identified in syngo.plaza VB30E (All versions < VB30E_HF05). The affected application do not p…
-
Critical 9.1
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not …