Vendor
Tenda
817 known vulnerabilities.
Products
817 results · Feed
-
High 8.8
Tenda CH22 NatStaticSetting fromNatStaticSetting buffer overflow
A flaw has been found in Tenda CH22 1.0.0.1. Affected by this issue is the function fromNatStaticSetting of the file /goform/NatStaticSetting. Executing a manipulation of the argument page can lead to buffer overflow. It is possible to launch the attack remot…
-
High 8.8
Tenda CH22 P2pListFilter fromP2pListFilter buffer overflow
A security vulnerability has been detected in Tenda CH22 1.0.0.1. Affected by this vulnerability is the function fromP2pListFilter of the file /goform/P2pListFilter. The manipulation of the argument page leads to buffer overflow. Remote exploitation of the at…
-
High 8.8
Tenda CH22 webExcptypemanFilter fromwebExcptypemanFilter buffer overflow
A weakness has been identified in Tenda CH22 1.0.0.1. Affected is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. Executing a manipulation of the argument page can lead to buffer overflow. The attack may be launched remotely. T…
-
High 8.8
Tenda CH22 addressNat fromAddressNat buffer overflow
A security flaw has been discovered in Tenda CH22 1.0.0.1. This impacts the function fromAddressNat of the file /goform/addressNat. Performing a manipulation of the argument page results in buffer overflow. The attack may be initiated remotely. The exploit ha…
-
High 8.8
Tenda CH22 RouteStatic fromRouteStatic buffer overflow
A vulnerability was identified in Tenda CH22 1.0.0.1. This affects the function fromRouteStatic of the file /goform/RouteStatic. Such manipulation of the argument page leads to buffer overflow. The attack can be launched remotely. The exploit is publicly avai…
-
High 8.8
Tenda CH22 VirtualSer fromVirtualSer buffer overflow
A weakness has been identified in Tenda CH22 1.0.0.1. Affected by this issue is the function fromVirtualSer of the file /goform/VirtualSer. This manipulation of the argument page causes buffer overflow. Remote exploitation of the attack is possible. The explo…
-
High 8.8
Tenda CH22 DhcpListClient fromDhcpListClient buffer overflow
A vulnerability was determined in Tenda CH22 1.0.0.1. This issue affects the function fromDhcpListClient of the file /goform/DhcpListClient. This manipulation of the argument page causes buffer overflow. Remote exploitation of the attack is possible. The expl…
-
High 8.0
Tenda CH22 SetIpBind fromSetIpBind buffer overflow
A vulnerability was found in Tenda CH22 1.0.0.1. This vulnerability affects the function fromSetIpBind of the file /goform/SetIpBind. The manipulation of the argument page results in buffer overflow. The attack must originate from the local network. The explo…
-
High 8.8
Tenda CH22 SafeMacFilter fromSafeMacFilter buffer overflow
A vulnerability has been found in Tenda CH22 1.0.0.1. This affects the function fromSafeMacFilter of the file /goform/SafeMacFilter. The manipulation of the argument page leads to buffer overflow. The attack may be initiated remotely. The exploit has been dis…
-
High 8.8
Tenda CH22 SafeUrlFilter fromSafeUrlFilter buffer overflow
A flaw has been found in Tenda CH22 1.0.0.1. Affected by this issue is the function fromSafeUrlFilter of the file /goform/SafeUrlFilter. Executing a manipulation of the argument page can lead to buffer overflow. The attack can be launched remotely. The exploi…
-
High 8.8
Tenda CH22 SafeClientFilter fromSafeClientFilter buffer overflow
A vulnerability was detected in Tenda CH22 1.0.0.1. Affected by this vulnerability is the function fromSafeClientFilter of the file /goform/SafeClientFilter. Performing a manipulation of the argument page results in buffer overflow. The attack can be initiate…
-
High 8.8
Tenda AC6 HTTP Request WifiGuestSet stack-based overflow
A vulnerability has been found in Tenda AC6 15.03.06.50. This issue affects some unknown processing of the file /goform/WifiGuestSet of the component HTTP Request Handler. Such manipulation of the argument shareSpeed leads to stack-based buffer overflow. The …
-
High 8.8
Tenda O3 sysAutoReboot GetValue stack-based overflow
A vulnerability was detected in Tenda O3 1.0.0.10(2478). This issue affects the function SetValue/GetValue of the file /goform/sysAutoReboot. Performing a manipulation of the argument enable results in stack-based buffer overflow. The attack may be initiated …
-
High 8.8
Tenda O3 setVlanConfig GetValue stack-based overflow
A security vulnerability has been detected in Tenda O3 1.0.0.10(2478). This vulnerability affects the function SetValue/GetValue of the file /goform/setVlanConfig. Such manipulation of the argument lan leads to stack-based buffer overflow. The attack can be l…
-
High 8.8
Tenda O3 setNetworkService GetValue stack-based overflow
A weakness has been identified in Tenda O3 1.0.0.10(2478). This affects the function SetValue/GetValue of the file /goform/setNetworkService. This manipulation of the argument upnpEn causes stack-based buffer overflow. The attack can be initiated remotely. Th…
-
High 8.8
Tenda O3 setDmzInfo GetValue stack-based overflow
A security flaw has been discovered in Tenda O3 1.0.0.10(2478). Affected by this issue is the function SetValue/GetValue of the file /goform/setDmzInfo. The manipulation of the argument dmzIP results in stack-based buffer overflow. It is possible to launch th…
-
High 8.8
Tenda O3 AdvSetLanip GetValue stack-based overflow
A vulnerability was identified in Tenda O3 1.0.0.10(2478). Affected by this vulnerability is the function SetValue/GetValue of the file /goform/AdvSetLanip. The manipulation of the argument lanIp leads to stack-based buffer overflow. It is possible to initiat…
-
High 8.8
Tenda O3 setDhcpConfig GetValue stack-based overflow
A vulnerability was determined in Tenda O3 1.0.0.10(2478). Affected is the function SetValue/GetValue of the file /goform/setDhcpConfig. Executing a manipulation of the argument dhcpEn can lead to stack-based buffer overflow. The attack may be performed from …
-
Medium 6.7
Tenda RP3 Pro Firmware Update force_upgrade.sh hard-coded password
A flaw has been found in Tenda RP3 Pro up to 22.5.7.93. This impacts an unknown function of the file force_upgrade.sh of the component Firmware Update Handler. Executing manipulation of the argument current_force_upgrade_pwd can lead to use of hard-coded pass…
-
High 8.8
Tenda AC7 setNotUpgrade stack-based overflow
A vulnerability was determined in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/setNotUpgrade. This manipulation of the argument newVersion causes stack-based buffer overflow. The attack is possible to be carried out remotely. Th…
-
Medium 6.5
Tenda W12 HTTP Request modules wifiScheduledSet null pointer dereference
A vulnerability was found in Tenda W12 3.0.0.6(3948). The impacted element is the function wifiScheduledSet of the file /goform/modules of the component HTTP Request Handler. The manipulation of the argument wifiScheduledSet results in null pointer dereferenc…
-
High 8.8
Tenda W12 HTTP Request modules wifiMacFilterSet stack-based overflow
A vulnerability has been found in Tenda W12 3.0.0.6(3948). The affected element is the function wifiMacFilterSet of the file /goform/modules of the component HTTP Request Handler. The manipulation of the argument mac leads to stack-based buffer overflow. The …
-
High 8.8
Tenda AC7 saveAutoQos stack-based overflow
A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit…
-
High 8.8
Tenda AC7 fast_setting_pppoe_set stack-based overflow
A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launc…
-
High 8.8
Tenda AC7 WifiMacFilterSet stack-based overflow
A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing a manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remo…
-
High 8.8
Tenda AC7 SetUpnpCfg stack-based overflow
A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been d…
-
High 8.8
Tenda AC7 SetDDNSCfg stack-based overflow
A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been …
-
Medium 6.3
Tenda AC7 AdvSetLanip command injection
A vulnerability was detected in Tenda AC7 15.03.06.44. This vulnerability affects unknown code of the file /goform/AdvSetLanip. The manipulation of the argument lanIp results in command injection. It is possible to launch the attack remotely. The exploit is n…
-
Critical 9.8
Tenda CH22 SafeEmailFilter formSafeEmailFilter memory corruption
A vulnerability was found in Tenda CH22 1.0.0.1. This affects the function formSafeEmailFilter of the file /goform/SafeEmailFilter. Performing a manipulation of the argument page results in memory corruption. The attack is possible to be carried out remotely.…
-
Critical 9.8
Tenda CH22 HTTP Request AdvSetWrlsafeset formWrlsafeset stack-based overflow
A security vulnerability has been detected in Tenda CH22 up to 1.0.0.1. This issue affects the function formWrlsafeset of the file /goform/AdvSetWrlsafeset of the component HTTP Request Handler. The manipulation of the argument mit_ssid_index leads to stack-b…
-
High 8.8
Tenda AC15 saveAutoQos stack-based overflow
A security flaw has been discovered in Tenda AC15 15.03.05.18. Affected is an unknown function of the file /goform/saveAutoQos. Performing a manipulation of the argument enable results in stack-based buffer overflow. Remote exploitation of the attack is possi…
-
High 8.8
Tenda AC15 setNotUpgrade stack-based overflow
A vulnerability was identified in Tenda AC15 15.03.05.18. This impacts an unknown function of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack may be launched remotely. The exploit i…
-
High 8.8
Tenda AC15 fast_setting_pppoe_set stack-based overflow
A vulnerability was determined in Tenda AC15 15.03.05.18. This affects an unknown function of the file /goform/fast_setting_pppoe_set. This manipulation of the argument Password causes stack-based buffer overflow. The attack may be initiated remotely. The exp…
-
High 8.8
Tenda AC15 POST Parameter SetDDNSCfg stack-based overflow
A vulnerability was found in Tenda AC15 15.03.05.18. The impacted element is an unknown function of the file /goform/SetDDNSCfg of the component POST Parameter Handler. The manipulation of the argument ddnsEn results in stack-based buffer overflow. The attack…
-
High 8.8
Tenda AC20 fast_setting_wifi_set sscanf buffer overflow
A vulnerability has been found in Tenda AC20 up to 16.03.08.12. The affected element is the function sscanf of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to buffer overflow. The attack can be initiated remotely. Th…
-
High 8.8
Tenda AC23 SetStaticRouteCfg sscanf buffer overflow
A vulnerability was found in Tenda AC23 up to 16.03.07.52. Affected by this issue is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. It is possible to launch the attack remotely. The…
-
High 8.8
Tenda AC18 SetDDNSCfg stack-based overflow
A vulnerability was detected in Tenda AC18 15.03.05.19(6318). This issue affects some unknown processing of the file /goform/SetDDNSCfg. The manipulation of the argument ddnsEn results in stack-based buffer overflow. It is possible to launch the attack remote…
-
High 8.8
Tenda AC18 SetUpnpCfg stack-based overflow
A security vulnerability has been detected in Tenda AC18 15.03.05.19(6318). This vulnerability affects unknown code of the file /goform/SetUpnpCfg. The manipulation of the argument upnpEn leads to stack-based buffer overflow. It is possible to initiate the at…
-
High 8.8
Tenda AC18 WifiMacFilterSet stack-based overflow
A weakness has been identified in Tenda AC18 15.03.05.19(6318). This affects an unknown part of the file /goform/WifiMacFilterSet. Executing a manipulation of the argument wifi_chkHz can lead to stack-based buffer overflow. The attack may be performed from re…
-
High 8.8
Tenda AC18 fast_setting_pppoe_set stack-based overflow
A security flaw has been discovered in Tenda AC18 15.03.05.19(6318). Affected by this issue is some unknown functionality of the file /goform/fast_setting_pppoe_set. Performing a manipulation of the argument Username results in stack-based buffer overflow. Th…