Description
Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime before 5.14.02, as used in ABB Interlink Module, IRC5 OPC Server, PC SDK, PickMaster 3 and 5, RobView 5, RobotStudio, WebWare SDK, and WebWare Server, allow remote attackers to execute arbitrary code via a crafted (1) 0xA or (2) 0xE Netscan packet.
Advisories 1
- ICSA-12-059-01 ABB Robot Communications Runtime Buffer Overflow CISA ICS & IT advisories · Jun 17, 2025
References
- 48090 third-party-advisory
- 52123 vdb-entry
- 20120222 ZDI-12-033 : ABB WebWare RobNetScanHost.exe Remote Code Execution Vulnerability mailing-list
- http://www.us-cert.gov/control_systems/pdf/ICSA-12-059-01.pdf
- http://www05.abb.com/global/scot/scot348.nsf/veritydisplay/f261be074480dc24c12579a00049ecd5/%24file/si10227a1%20vulnerability%20security%20advisory.pdf
- http://www.zerodayinitiative.com/advisories/ZDI-12-033/