Description
Stack-based buffer overflow in RunTime.exe in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allows remote attackers to execute arbitrary code via a crafted port-46824 TCP packet that triggers an incorrect file-open attempt by the _TCPIPS_BinOpenFileFP function, a different vulnerability than CVE-2012-3815. NOTE: some of these details are obtained from third party information.
Public exploits
Exploit or proof-of-concept code for this vulnerability is publicly available, which lowers the bar for attackers. Treat it as a reason to patch sooner.
Exploit-DB 1
- Sielco Sistemi Winlog 2.07.16 - Multiple Vulnerabilities EDB-19409 · dos · Jun 27, 2012 · verified
Sources: PoC-in-GitHub, Metasploit Framework, Exploit-DB — updated daily. Only links are listed; no exploit code is hosted here.
Advisories 1
- ICSA-12-213-01A Sielco Sistemi Winlog Multiple Vulnerabilities CISA ICS & IT advisories · Jun 5, 2025