Skip to content
OpenAdvisories
Unscored CVE-2017-6015 EUVD-2017-15083GHSA-rfr4-xxfq-6j5j

Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, …

Published May 11, 2018 · Updated Sep 16, 2024 · Assigned by icscert

Description

Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.

Affected products

VendorProductAffectedFixed
Rockwell Automation FactoryTalk Activation FactoryTalk Activation Service, Version 4.00.02 and prior versions. —

Advisories 1

References