Description
Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.
Affected products
| Vendor | Product | Affected | Fixed |
|---|---|---|---|
| Rockwell Automation | FactoryTalk Activation | FactoryTalk Activation Service, Version 4.00.02 and prior versions. | — |
Advisories 1
- ICSA-17-047-02 Rockwell Automation FactoryTalk Activation CISA ICS & IT advisories · Mar 21, 2017