High · 7.5 Known exploited Scanner template Public exploit CVE-2018-0296 EUVD-2018-1119GHSA-h2mj-pqgp-xmmj

A vulnerability in the web interface of the Cisco Adaptive Security Appliance (ASA) could allow an unauthenticated, remote attacker to caus…

Published Jun 7, 2018 · Updated Jan 12, 2026 · Assigned by cisco

Description

A vulnerability in the web interface of the Cisco Adaptive Security Appliance (ASA) could allow an unauthenticated, remote attacker to cause an affected device to reload unexpectedly, resulting in a denial of service (DoS) condition. It is also possible on certain software releases that the ASA will not reload, but an attacker could view sensitive system information without authentication by using directory traversal techniques. The vulnerability is due to lack of proper input validation of the HTTP URL. An attacker could exploit this vulnerability by sending a crafted HTTP request to an affected device. An exploit could allow the attacker to cause a DoS condition or unauthenticated disclosure of information. This vulnerability applies to IPv4 and IPv6 HTTP traffic. This vulnerability affects Cisco ASA Software and Cisco Firepower Threat Defense (FTD) Software that is running on the following Cisco products: 3000 Series Industrial Security Appliance (ISA), ASA 1000V Cloud Firewall, ASA 5500 Series Adaptive Security Appliances, ASA 5500-X Series Next-Generation Firewalls, ASA Services Module for Cisco Catalyst 6500 Series Switches and Cisco 7600 Series Routers, Adaptive Security Virtual Appliance (ASAv), Firepower 2100 Series Security Appliance, Firepower 4100 Series Security Appliance, Firepower 9300 ASA Security Module, FTD Virtual (FTDv). Cisco Bug IDs: CSCvi16029.

Affected products

VendorProductAffectedFixed
— Cisco Adaptive Security Appliance unknown Cisco Adaptive Security Appliance unknown —

Public exploits

Exploit or proof-of-concept code for this vulnerability is publicly available, which lowers the bar for attackers. Treat it as a reason to patch sooner.

Third-party code, not reviewed by us. Public PoCs are sometimes fake or contain malware. Read the code first and run it only in an isolated lab, against systems you are authorised to test.

Metasploit 1 module

Exploit-DB 2

GitHub 4 repositories

Sources: PoC-in-GitHub, Metasploit Framework, Exploit-DB — updated daily. Only links are listed; no exploit code is hosted here.

Automated scanner template

A ready-made Nuclei template detects this vulnerability automatically. Vulnerabilities with public scanner templates are typically probed across the internet soon after the template appears — exposed systems should be patched first.

Source: projectdiscovery/nuclei-templates (MIT) — updated daily. Only links are listed.