Skip to content
OpenAdvisories
Critical · 9.4 CVE-2018-5399 EUVD-2018-17169GHSA-qxxm-7g2q-pwxw

The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running and is configured with a hard-coded credentials

Published Oct 8, 2018 · Updated Sep 17, 2024 · Assigned by certcc

Description

The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7.

Affected products

VendorProductAffectedFixed
Auto-Maskin DCU-210E 3.7 – < 3.7 3.7
Auto-Maskin RP-210E 3.7 – < 3.7 3.7