Skip to content
OpenAdvisories
High · 7.5 CVE-2021-25664 EUVD-2021-12556GHSA-q7wx-433j-27hv

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions…

Published Apr 22, 2021 · Updated Mar 11, 2025 · Assigned by siemens

Description

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes the Hop-by-Hop extension header in IPv6 packets and its options lacks any checks against the length field of the header, allowing attackers to put the function into an infinite loop by supplying arbitrary length values.

Affected products

VendorProductAffectedFixed
Siemens Capital Embedded AR Classic 431-422 — —
Siemens Capital Embedded AR Classic R20-11 < V2303 V2303
Siemens Nucleus NET All versions —
Siemens Nucleus ReadyStart V3 < V2017.02.4 V2017.02.4
Siemens Nucleus ReadyStart V4 < V4.1.0 V4.1.0
Siemens Nucleus Source Code — —

Advisories 3

References