Description
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z, and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.065T allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.
Affected products
| Vendor | Product | Affected | Fixed |
|---|---|---|---|
| Mitsubishi Electric | GX Works3 | from 1.000A to 1.095Z | — |
| Mitsubishi Electric | Motion Control Setting(GX Works3 related software) | from 1.000A to 1.065T | — |
Advisories 1
- ICSA-22-333-05 Mitsubishi Electric FA Engineering Software (Update C) CISA ICS & IT advisories · Nov 25, 2025
References
- https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf vendor-advisory
- https://jvn.jp/vu/JVNVU97244961/index.html government-resource