Skip to content
OpenAdvisories
High · 7.8 CVE-2022-39157 EUVD-2022-41702GHSA-5m2g-whv8-xj9q

A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.0 (All versions >= V34.0.252 < V34.0.254),…

Published Nov 8, 2022 · Updated Apr 21, 2025 · Assigned by siemens

Description

A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.0 (All versions >= V34.0.252 < V34.0.254), Parasolid V34.1 (All versions < V34.1.242), Parasolid V34.1 (All versions >= V34.1.242 < V34.1.244), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.0 (All versions >= V35.0.170 < V35.0.184), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17745)

Affected products

VendorProductAffectedFixed
Siemens Parasolid V34.0 All versions < V34.0.252, All versions >= V34.0.252 < V34.0.254 —
Siemens Parasolid V34.1 All versions < V34.1.242, All versions >= V34.1.242 < V34.1.244 —
Siemens Parasolid V35.0 All versions < V35.0.170, All versions >= V35.0.170 < V35.0.184 —
Siemens Simcenter Femap All versions < V2023.1 —

Advisories 4

References