Description
A vulnerability has been identified in SICAM P850 (7KG8500-0AA00-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA00-2AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA10-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA10-2AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA30-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA30-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA01-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA01-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA02-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA02-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA11-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA11-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA12-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA12-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA31-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA31-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA32-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA32-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA00-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA00-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA10-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA10-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA30-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA30-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA01-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA01-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA02-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA02-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA11-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA11-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA12-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA12-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA31-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA31-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA32-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA32-2AA0) (All versions < V3.10), SICAM T (All versions < V3.0). Affected devices do not properly validate the parameter of a specific GET request. This could allow an unauthenticated attacker to set the device to a denial of service state or to control the program counter and, thus, execute arbitrary code on the device.
Affected products
| Vendor | Product | Affected | Fixed |
|---|---|---|---|
| Siemens | SICAM P850 | All versions < V3.10 | — |
| Siemens | SICAM P855 | All versions < V3.10 | — |
| Siemens | SICAM T | < V3.0 | V3.0 |
Advisories 5
- NCSC-2025-0382 Kwetsbaarheden verholpen in Siemens producten NCSC-NL (Netherlands) · Dec 9, 2025
- SSA-471761 SSA-471761: Multiple Vulnerabilities in SICAM T Before V3.0 Siemens ProductCERT · Dec 9, 2025
- WID-SEC-2022-1673 Siemens SICAM: Mehrere Schwachstellen BSI CERT-Bund (WID) · Dec 8, 2025
- ICSA-22-286-09 Siemens SICAM P850 and P855 Devices CISA ICS & IT advisories · May 6, 2025
- SSA-572005 SSA-572005: Vulnerabilities in the Web Server of SICAM P850 and SICAM P855 Devices Siemens ProductCERT · Jun 13, 2023