Skip to content
OpenAdvisories

Description

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.

Affected products

VendorProductAffectedFixed
Siemens Opcenter Execution Foundation < V2407 V2407
Siemens Opcenter Quality < V2312 V2312
Siemens SIMATIC PCS neo < V4.1 V4.1
Siemens SINEC NMS < V2.0 SP1 V2.0 SP1
Siemens Totally Integrated Automation Portal (TIA Portal) V14 — —
Siemens Totally Integrated Automation Portal (TIA Portal) V15.1 — —
Siemens Totally Integrated Automation Portal (TIA Portal) V16 — —
Siemens Totally Integrated Automation Portal (TIA Portal) V17 < V17 Update 8 V17 Update 8
Siemens Totally Integrated Automation Portal (TIA Portal) V18 < V18 Update 3 V18 Update 3

Advisories 3

References