Description
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Affected products
| Vendor | Product | Affected | Fixed |
|---|---|---|---|
| Tenda | AC7 | 15.03.06.44 | — |
References
- VDB-257934 | Tenda AC7 QuickIndex formQuickIndex stack-based overflow vdb-entry technical-description
- VDB-257934 | CTI Indicators (IOB, IOC, IOA) signature permissions-required
- Submit #300354 | Tenda AC7 AC7V1.0 V15.03.06.44 buffer overflow third-party-advisory
- https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formQuickIndex.md exploit