Description
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Affected products
| Vendor | Product | Affected | Fixed |
|---|---|---|---|
| Tenda | AC7 | 15.03.06.44 | — |
References
- VDB-257937 | Tenda AC7 SetNetControlList formSetQosBand stack-based overflow vdb-entry technical-description
- VDB-257937 | CTI Indicators (IOB, IOC, IOA) signature permissions-required
- Submit #300357 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow third-party-advisory
- https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetQosBand.md exploit