Description
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected application does not properly limit the size of specific logs. This could allow an unauthenticated remote attacker to exhaust system resources by creating a great number of log entries which could potentially lead to a denial of service condition. A successful exploitation requires the attacker to have access to specific SIMATIC RTLS Locating Manager Clients in the deployment.
Affected products
| Vendor | Product | Affected | Fixed |
|---|---|---|---|
| Siemens | SIMATIC RTLS Locating Manager | < V3.0.1.1 | V3.0.1.1 |
Advisories 2
- ICSA-24-137-07 Siemens SIMATIC RTLS Locating Manager CISA ICS & IT advisories · Jun 11, 2024
- SSA-093430 SSA-093430: Multiple Vulnerabilities in SIMATIC RTLS Locating Manager before V3.0 Siemens ProductCERT · Jun 11, 2024