Skip to content
OpenAdvisories
High · 8.8 CVE-2025-32840 EUVD-2025-11427GHSA-h4p7-4v4q-3q54

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL in…

Published Apr 16, 2025 · Updated Apr 17, 2025 · Assigned by siemens

Description

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockGateway' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Affected products

VendorProductAffectedFixed
Siemens TeleControl Server Basic < V3.1.2.2 V3.1.2.2

Advisories 3

References